Schneider Electric Geo SCADA Mobile up to Build 222 exposure of resource

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.0$0-$5k0.00

Summaryinfo

A vulnerability identified as critical has been detected in Schneider Electric Geo SCADA Mobile up to Build 222. The affected element is an unknown function. Performing a manipulation results in exposure of resource. This vulnerability is cataloged as CVE-2022-32530. It is possible to initiate the attack remotely. There is no exploit available.

Detailsinfo

A vulnerability was found in Schneider Electric Geo SCADA Mobile up to Build 222 (SCADA Software). It has been classified as critical. This affects some unknown functionality. The manipulation with an unknown input leads to a exposure of resource vulnerability. CWE is classifying the issue as CWE-668. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)

The weakness was shared 06/24/2022. This vulnerability is uniquely identified as CVE-2022-32530 since 06/07/2022. It demands that the victim is doing some kind of user interaction. The technical details are unknown and an exploit is not publicly available.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.0
VulDB Meta Temp Score: 6.0

VulDB Base Score: 5.5
VulDB Temp Score: 5.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.8
NVD Vector: 🔍

CNA Base Score: 4.8
CNA Vector (Schneider Electric SE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Exposure of resource
CWE: CWE-668 / CWE-200 / CWE-284
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

06/07/2022 🔍
06/24/2022 +17 days 🔍
06/24/2022 +0 days 🔍
07/14/2022 +20 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: download.schneider-electric.com
Status: Confirmed

CVE: CVE-2022-32530 (🔍)
GCVE (CVE): GCVE-0-2022-32530
GCVE (VulDB): GCVE-100-202659

Entryinfo

Created: 06/24/2022 16:33
Updated: 07/14/2022 14:12
Changes: 06/24/2022 16:33 (46), 07/14/2022 14:09 (1), 07/14/2022 14:12 (18)
Complete: 🔍
Cache ID: 216::103

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to know what is going to be exploited?

We predict KEV entries!