Schneider Electric EcoStruxure Control Expert Modbus password recovery

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
8.5$0-$5k0.00

Summaryinfo

A vulnerability was found in Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, EcoStruxure Hybrid DCS, Modicon M340 CPU and Modicon M580 CPU and classified as critical. Affected by this issue is some unknown functionality of the component Modbus Handler. Such manipulation leads to password recovery. This vulnerability is uniquely identified as CVE-2022-37300. The attack can be launched remotely. No exploit exists.

Detailsinfo

A vulnerability, which was classified as critical, has been found in Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, EcoStruxure Hybrid DCS, Modicon M340 CPU and Modicon M580 CPU (SCADA Software). Affected by this issue is an unknown code of the component Modbus Handler. The manipulation with an unknown input leads to a password recovery vulnerability. Using CWE to declare the problem leads to CWE-640. The product contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak. Impacted is confidentiality, integrity, and availability. CVE summarizes:

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).

The weakness was disclosed 09/13/2022 as SEVD-2022-221-01. The advisory is shared for download at se.com. This vulnerability is handled as CVE-2022-37300 since 08/01/2022. There are neither technical details nor an exploit publicly available. The current price for an exploit might be approx. USD $0-$5k (estimation calculated on 09/13/2022). The MITRE ATT&CK project declares the attack technique as T1552.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 8.5
VulDB Meta Temp Score: 8.5

VulDB Base Score: 7.3
VulDB Temp Score: 7.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 9.8
CNA Vector (Schneider Electric SE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Password recovery
CWE: CWE-640
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

08/01/2022 🔍
09/13/2022 +43 days 🔍
09/13/2022 +0 days 🔍
09/13/2022 +0 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2022-221-01
Status: Confirmed

CVE: CVE-2022-37300 (🔍)
GCVE (CVE): GCVE-0-2022-37300
GCVE (VulDB): GCVE-100-208352

Entryinfo

Created: 09/13/2022 10:29
Changes: 09/13/2022 10:29 (48)
Complete: 🔍
Cache ID: 216::103

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!