Siemens Parasolid/Simcenter Femap X_T File out-of-bounds write
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 6.9 | $0-$5k | 0.00 |
Summary
A vulnerability marked as critical has been reported in Siemens Parasolid and Simcenter Femap. Affected by this vulnerability is an unknown functionality of the component X_T File Handler. The manipulation leads to out-of-bounds write. This vulnerability is listed as CVE-2022-39142. The attack may be initiated remotely. There is no available exploit. It is suggested to upgrade the affected component.
Details
A vulnerability was found in Siemens Parasolid and Simcenter Femap (the affected version is unknown) and classified as critical. This issue affects an unknown code of the component X_T File Handler. The manipulation with an unknown input leads to a out-of-bounds write vulnerability. Using CWE to declare the problem leads to CWE-787. The product writes data past the end, or before the beginning, of the intended buffer. Impacted is confidentiality, integrity, and availability. The summary by CVE is:
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17485)
The weakness was presented 09/13/2022 as ZDI-CAN-17485. The advisory is shared at cert-portal.siemens.com. The identification of this vulnerability is CVE-2022-39142 since 09/01/2022. It demands that the victim is doing some kind of user interaction. Neither technical details nor an exploit are publicly available.
Upgrading eliminates this vulnerability.
If you want to get the best quality for vulnerability data then you always have to consider VulDB.
Product
Vendor
Name
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 7.0VulDB Meta Temp Score: 6.9
VulDB Base Score: 6.3
VulDB Temp Score: 6.0
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 7.8
NVD Vector: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Out-of-bounds writeCWE: CWE-787 / CWE-119
CAPEC: 🔍
ATT&CK: 🔍
Physical: Partially
Local: Yes
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Timeline
09/01/2022 🔍09/13/2022 🔍
09/13/2022 🔍
10/15/2022 🔍
Sources
Vendor: siemens.comAdvisory: ZDI-CAN-17485
Status: Confirmed
CVE: CVE-2022-39142 (🔍)
GCVE (CVE): GCVE-0-2022-39142
GCVE (VulDB): GCVE-100-208373
Entry
Created: 09/13/2022 16:20Updated: 10/15/2022 15:48
Changes: 09/13/2022 16:20 (39), 10/15/2022 15:48 (11)
Complete: 🔍
Cache ID: 216::103
If you want to get the best quality for vulnerability data then you always have to consider VulDB.
No comments yet. Languages: en.
Please log in to comment.