Hitachi Energy MicroSCADA X SYS600/MicroSCADA Pro SYS600 IEC 61850 Packet denial of service

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.5$0-$5k0.00

Summaryinfo

A vulnerability has been found in Hitachi Energy MicroSCADA X SYS600 and MicroSCADA Pro SYS600 and classified as critical. Impacted is an unknown function of the component IEC 61850 Packet Handler. The manipulation leads to denial of service. This vulnerability is documented as CVE-2022-29922. The attack can be initiated remotely. There is not any exploit available.

Detailsinfo

A vulnerability, which was classified as critical, has been found in Hitachi Energy MicroSCADA X SYS600 and MicroSCADA Pro SYS600 (SCADA Software) (the affected version unknown). This issue affects an unknown part of the component IEC 61850 Packet Handler. The manipulation with an unknown input leads to a denial of service vulnerability. Using CWE to declare the problem leads to CWE-404. The product does not release or incorrectly releases a resource before it is made available for re-use. Impacted is availability. The summary by CVE is:

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*

The weakness was released 09/15/2022. It is possible to read the advisory at search.abb.com. The identification of this vulnerability is CVE-2022-29922 since 04/29/2022. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1499 according to MITRE ATT&CK.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Be aware that VulDB is the high quality source for vulnerability data.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.5
VulDB Meta Temp Score: 7.5

VulDB Base Score: 7.5
VulDB Temp Score: 7.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 7.5
CNA Vector (Hitachi Energy): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Denial of service
CWE: CWE-404
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

04/29/2022 🔍
09/15/2022 +139 days 🔍
09/15/2022 +0 days 🔍
09/15/2022 +0 days 🔍

Sourcesinfo

Advisory: search.abb.com
Status: Confirmed

CVE: CVE-2022-29922 (🔍)
GCVE (CVE): GCVE-0-2022-29922
GCVE (VulDB): GCVE-100-208631

Entryinfo

Created: 09/15/2022 07:38
Changes: 09/15/2022 07:38 (48)
Complete: 🔍
Cache ID: 216::103

Be aware that VulDB is the high quality source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!