Siemens SIMATIC Drive Controller Global Key insufficiently protected credentials

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.6$0-$5k0.00

Summaryinfo

A vulnerability was found in Siemens SIMATIC Drive Controller, SIMATIC ET 200SP Open Controller CPU 1515SP PC, SIMATIC ET 200SP Open Controller CPU 1515SP PC2, SIMATIC S7-1200 CPU, SIMATIC S7-1500 CPU, SIMATIC S7-1500 Software Controller and SIMATIC S7-PLCSIM Advanced and classified as problematic. Impacted is an unknown function of the component Global Key Handler. Executing a manipulation can lead to insufficiently protected credentials. The identification of this vulnerability is CVE-2022-38465. There is no exploit available. It is suggested to upgrade the affected component.

Detailsinfo

A vulnerability has been found in Siemens SIMATIC Drive Controller, SIMATIC ET 200SP Open Controller CPU 1515SP PC, SIMATIC ET 200SP Open Controller CPU 1515SP PC2, SIMATIC S7-1200 CPU, SIMATIC S7-1500 CPU, SIMATIC S7-1500 Software Controller and SIMATIC S7-PLCSIM Advanced (SCADA Software) and classified as problematic. This vulnerability affects an unknown code of the component Global Key Handler. The manipulation with an unknown input leads to a insufficiently protected credentials vulnerability. The CWE definition for the vulnerability is CWE-522. The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval. As an impact it is known to affect confidentiality. CVE summarizes:

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.

The weakness was shared 10/11/2022 as ssa-568427. The advisory is shared for download at cert-portal.siemens.com. This vulnerability was named CVE-2022-38465 since 08/19/2022. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1552.

Upgrading eliminates this vulnerability.

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.6
VulDB Meta Temp Score: 5.6

VulDB Base Score: 3.5
VulDB Temp Score: 3.4
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.8
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Insufficiently protected credentials
CWE: CWE-522
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: Partially

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Timelineinfo

08/19/2022 🔍
10/11/2022 +53 days 🔍
10/11/2022 +0 days 🔍
11/05/2022 +25 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-568427
Status: Confirmed

CVE: CVE-2022-38465 (🔍)
GCVE (CVE): GCVE-0-2022-38465
GCVE (VulDB): GCVE-100-210424

Entryinfo

Created: 10/11/2022 16:10
Updated: 11/05/2022 08:35
Changes: 10/11/2022 16:10 (39), 11/05/2022 08:35 (11)
Complete: 🔍
Cache ID: 216::103

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Might our Artificial Intelligence support you?

Check our Alexa App!