Siemens SIMATIC WinCC OA up to 3.14/3.15/3.16/3.17 Web Interface argument injection

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.7$0-$5k0.00

Summaryinfo

A vulnerability categorized as critical has been discovered in Siemens SIMATIC WinCC OA up to 3.14/3.15/3.16/3.17. Affected by this vulnerability is an unknown functionality of the component Web Interface Handler. Such manipulation leads to argument injection. This vulnerability is listed as CVE-2022-44731. The attack may be performed from remote. There is no available exploit. It is advisable to implement a patch to correct this issue.

Detailsinfo

A vulnerability was found in Siemens SIMATIC WinCC OA up to 3.14/3.15/3.16/3.17 (SCADA Software). It has been rated as critical. Affected by this issue is an unknown functionality of the component Web Interface Handler. The manipulation with an unknown input leads to a argument injection vulnerability. Using CWE to declare the problem leads to CWE-88. The product constructs a string for a command to be executed by a separate component in another control sphere, but it does not properly delimit the intended arguments, options, or switches within that command string. Impacted is confidentiality, integrity, and availability. CVE summarizes:

A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script).

The weakness was presented 12/13/2022 as ssa-547714. The advisory is shared for download at cert-portal.siemens.com. This vulnerability is handled as CVE-2022-44731 since 11/04/2022. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1059.

Applying a patch is able to eliminate this problem.

Once again VulDB remains the best source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.9
VulDB Meta Temp Score: 5.7

VulDB Base Score: 6.3
VulDB Temp Score: 6.0
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 5.4
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Argument injection
CWE: CWE-88 / CWE-74 / CWE-707
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Patch
Status: 🔍

0-Day Time: 🔍

Timelineinfo

11/04/2022 🔍
12/13/2022 +39 days 🔍
12/13/2022 +0 days 🔍
01/07/2023 +25 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-547714
Status: Confirmed

CVE: CVE-2022-44731 (🔍)
GCVE (CVE): GCVE-0-2022-44731
GCVE (VulDB): GCVE-100-215468

Entryinfo

Created: 12/13/2022 19:01
Updated: 01/07/2023 17:15
Changes: 12/13/2022 19:01 (41), 01/07/2023 17:15 (11)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!