Siemens SIMATIC WinCC OA up to 3.14/3.15/3.16/3.17 Web Interface argument injection
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 5.7 | $0-$5k | 0.00 |
Summary
A vulnerability categorized as critical has been discovered in Siemens SIMATIC WinCC OA up to 3.14/3.15/3.16/3.17. Affected by this vulnerability is an unknown functionality of the component Web Interface Handler. Such manipulation leads to argument injection. This vulnerability is listed as CVE-2022-44731. The attack may be performed from remote. There is no available exploit. It is advisable to implement a patch to correct this issue.
Details
A vulnerability was found in Siemens SIMATIC WinCC OA up to 3.14/3.15/3.16/3.17 (SCADA Software). It has been rated as critical. Affected by this issue is an unknown functionality of the component Web Interface Handler. The manipulation with an unknown input leads to a argument injection vulnerability. Using CWE to declare the problem leads to CWE-88. The product constructs a string for a command to be executed by a separate component
in another control sphere, but it does not properly delimit the
intended arguments, options, or switches within that command string. Impacted is confidentiality, integrity, and availability. CVE summarizes:
A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script).
The weakness was presented 12/13/2022 as ssa-547714. The advisory is shared for download at cert-portal.siemens.com. This vulnerability is handled as CVE-2022-44731 since 11/04/2022. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1059.
Applying a patch is able to eliminate this problem.
Once again VulDB remains the best source for vulnerability data.
Product
Type
Vendor
Name
Version
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 5.9VulDB Meta Temp Score: 5.7
VulDB Base Score: 6.3
VulDB Temp Score: 6.0
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 5.4
NVD Vector: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Argument injectionCWE: CWE-88 / CWE-74 / CWE-707
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: PatchStatus: 🔍
0-Day Time: 🔍
Timeline
11/04/2022 🔍12/13/2022 🔍
12/13/2022 🔍
01/07/2023 🔍
Sources
Vendor: siemens.comAdvisory: ssa-547714
Status: Confirmed
CVE: CVE-2022-44731 (🔍)
GCVE (CVE): GCVE-0-2022-44731
GCVE (VulDB): GCVE-100-215468
Entry
Created: 12/13/2022 19:01Updated: 01/07/2023 17:15
Changes: 12/13/2022 19:01 (41), 01/07/2023 17:15 (11)
Complete: 🔍
Cache ID: 216::103
Once again VulDB remains the best source for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.