Schneider Electric Data Center Expert 7.4.0 password recoverable

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.9$0-$5k0.00

Summaryinfo

A vulnerability classified as problematic has been found in Schneider Electric Data Center Expert. Affected by this vulnerability is an unknown functionality. Performing a manipulation results in password recoverable. This vulnerability was named CVE-2022-32519. The attack may be initiated remotely. There is no available exploit. It is recommended to upgrade the affected component.

Detailsinfo

A vulnerability was found in Schneider Electric Data Center Expert (SCADA Software). It has been classified as problematic. This affects some unknown processing. The manipulation with an unknown input leads to a password recoverable vulnerability. CWE is classifying the issue as CWE-257. The storage of passwords in a recoverable format makes them subject to password reuse attacks by malicious users. In fact, it should be noted that recoverable encrypted passwords provide no significant benefit over plaintext passwords since they are subject not only to reuse by malicious attackers but also by malicious insiders. If a system administrator can recover a password directly, or use a brute force search on the available information, the administrator can use the password on other accounts. This is going to have an impact on confidentiality. The summary by CVE is:

A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)

The weakness was presented 01/31/2023 as SEVD-2022-165-04. The advisory is shared at download.schneider-electric.com. This vulnerability is uniquely identified as CVE-2022-32519 since 06/07/2022. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1552 for this issue.

Upgrading to version 7.9.0 eliminates this vulnerability.

The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2022-35590). If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.0
VulDB Meta Temp Score: 6.9

VulDB Base Score: 3.1
VulDB Temp Score: 3.0
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 9.8
NVD Vector: 🔍

CNA Base Score: 8.0
CNA Vector (Schneider Electric SE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Password recoverable
CWE: CWE-257 / CWE-255
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: Data Center Expert 7.9.0

Timelineinfo

06/07/2022 🔍
01/31/2023 +238 days 🔍
01/31/2023 +0 days 🔍
05/29/2026 +1214 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2022-165-04
Status: Confirmed

CVE: CVE-2022-32519 (🔍)
GCVE (CVE): GCVE-0-2022-32519
GCVE (VulDB): GCVE-100-219813
EUVD: 🔍

Entryinfo

Created: 01/31/2023 14:31
Updated: 05/29/2026 16:03
Changes: 01/31/2023 14:31 (49), 02/25/2023 16:50 (11), 05/29/2026 16:03 (17)
Complete: 🔍
Cache ID: 216::103