Schneider Electric IGSS Data Server/IGSS Dashboard/Custom Reports up to 16.0.0.23040 missing authentication

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
8.6$0-$5k0.00

Summaryinfo

A vulnerability labeled as critical has been found in Schneider Electric IGSS Data Server, IGSS Dashboard and Custom Reports up to 16.0.0.23040. The impacted element is an unknown function. Executing a manipulation can lead to missing authentication. This vulnerability is registered as CVE-2023-27980. It is possible to launch the attack remotely. No exploit is available. A patch should be applied to remediate this issue.

Detailsinfo

A vulnerability was found in Schneider Electric IGSS Data Server, IGSS Dashboard and Custom Reports up to 16.0.0.23040 (SCADA Software). It has been declared as critical. This vulnerability affects an unknown part. The manipulation with an unknown input leads to a missing authentication vulnerability. The CWE definition for the vulnerability is CWE-306. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. As an impact it is known to affect confidentiality, integrity, and availability. CVE summarizes:

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)

The weakness was published 03/21/2023 as SEVD-2023-073-04. The advisory is available at download.schneider-electric.com. This vulnerability was named CVE-2023-27980 since 03/09/2023. Successful exploitation requires user interaction by the victim. The technical details are unknown and an exploit is not available.

Applying a patch is able to eliminate this problem.

The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2023-31706). If you want to get best quality of vulnerability data, you may have to visit VulDB.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 8.8
VulDB Meta Temp Score: 8.6

VulDB Base Score: 8.8
VulDB Temp Score: 8.4
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 8.8
CNA Vector (Schneider Electric SE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Missing authentication
CWE: CWE-306 / CWE-287
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Patch
Status: 🔍

0-Day Time: 🔍

Timelineinfo

03/09/2023 🔍
03/21/2023 +12 days 🔍
03/21/2023 +0 days 🔍
11/30/2025 +985 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2023-073-04
Status: Confirmed

CVE: CVE-2023-27980 (🔍)
GCVE (CVE): GCVE-0-2023-27980
GCVE (VulDB): GCVE-100-223450
EUVD: 🔍

Entryinfo

Created: 03/21/2023 08:24
Updated: 11/30/2025 09:03
Changes: 03/21/2023 08:24 (50), 11/30/2025 09:03 (16)
Complete: 🔍
Cache ID: 216::103

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!