Siemens SIMATIC CP 1242-7 V2 Webserver denial of service

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.3$0-$5k0.00

Summaryinfo

A vulnerability described as problematic has been identified in Siemens SIMATIC CP 1242-7 V2, SIMATIC CP 1243-1, SIMATIC CP 1243-1 DNP3, SIMATIC CP 1243-1 IEC, SIMATIC CP 1243-7 LTE EU, SIMATIC CP 1243-7 LTE US, SIMATIC CP 1243-8 IRC, SIMATIC CP 1542SP-1, SIMATIC CP 1542SP-1 IRC, SIMATIC CP 1543SP-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor. The impacted element is an unknown function of the component Webserver. Executing a manipulation can lead to denial of service. This vulnerability is handled as CVE-2022-43767. The attack can be executed remotely. There is not any exploit available. Upgrading the affected component is recommended.

Detailsinfo

A vulnerability classified as critical was found in Siemens SIMATIC CP 1242-7 V2, SIMATIC CP 1243-1, SIMATIC CP 1243-1 DNP3, SIMATIC CP 1243-1 IEC, SIMATIC CP 1243-7 LTE EU, SIMATIC CP 1243-7 LTE US, SIMATIC CP 1243-8 IRC, SIMATIC CP 1542SP-1, SIMATIC CP 1542SP-1 IRC, SIMATIC CP 1543SP-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor (SCADA Software). This vulnerability affects an unknown code block of the component Webserver. The manipulation with an unknown input leads to a denial of service vulnerability. The CWE definition for the vulnerability is CWE-404. The product does not release or incorrectly releases a resource before it is made available for re-use. As an impact it is known to affect availability. CVE summarizes:

A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.

The weakness was released 04/11/2023 as ssa-566905. The advisory is shared for download at cert-portal.siemens.com. This vulnerability was named CVE-2022-43767 since 10/26/2022. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1499.

Upgrading eliminates this vulnerability.

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.5
VulDB Meta Temp Score: 7.3

VulDB Base Score: 7.5
VulDB Temp Score: 7.2
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 7.5
CNA Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Denial of service
CWE: CWE-404
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Timelineinfo

10/26/2022 🔍
04/11/2023 +167 days 🔍
04/11/2023 +0 days 🔍
04/11/2023 +0 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-566905
Status: Confirmed

CVE: CVE-2022-43767 (🔍)
GCVE (CVE): GCVE-0-2022-43767
GCVE (VulDB): GCVE-100-225496

Entryinfo

Created: 04/11/2023 13:31
Changes: 04/11/2023 13:31 (49)
Complete: 🔍
Cache ID: 216::103

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to stay up to date on a daily basis?

Enable the mail alert feature now!