| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 4.4 | $0-$5k | 0.00 |
Summary
A vulnerability labeled as problematic has been found in Siemens SIMATIC CP 1604, SIMATIC CP 1616, SIMATIC CP 1623, SIMATIC CP 1626 and SIMATIC CP 1628. Affected by this vulnerability is an unknown functionality of the component DMA. The manipulation results in resource consumption. This vulnerability is reported as CVE-2023-37195. The attack requires a local approach. No exploit exists.
Details
A vulnerability was found in Siemens SIMATIC CP 1604, SIMATIC CP 1616, SIMATIC CP 1623, SIMATIC CP 1626 and SIMATIC CP 1628 (SCADA Software). It has been classified as problematic. Affected is an unknown part of the component DMA. The manipulation with an unknown input leads to a resource consumption vulnerability. CWE is classifying the issue as CWE-400. The product does not properly control the allocation and maintenance of a limited resource, thereby enabling an actor to influence the amount of resources consumed, eventually leading to the exhaustion of available resources. This is going to have an impact on availability. CVE summarizes:
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
The weakness was disclosed 10/10/2023 as ssa-784849. The advisory is shared for download at cert-portal.siemens.com. This vulnerability is traded as CVE-2023-37195 since 06/28/2023. There are neither technical details nor an exploit publicly available.
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
Once again VulDB remains the best source for vulnerability data.
Product
Type
Vendor
Name
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 4.4VulDB Meta Temp Score: 4.4
VulDB Base Score: 4.4
VulDB Temp Score: 4.4
VulDB Vector: 🔍
VulDB Reliability: 🔍
CNA Base Score: 4.4
CNA Vector (Siemens AG): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Resource consumptionCWE: CWE-400 / CWE-404
CAPEC: 🔍
ATT&CK: 🔍
Physical: Partially
Local: Yes
Remote: No
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
Timeline
06/28/2023 🔍10/10/2023 🔍
10/10/2023 🔍
10/10/2023 🔍
Sources
Vendor: siemens.comAdvisory: ssa-784849
Status: Confirmed
CVE: CVE-2023-37195 (🔍)
GCVE (CVE): GCVE-0-2023-37195
GCVE (VulDB): GCVE-100-241692
Entry
Created: 10/10/2023 13:51Changes: 10/10/2023 13:51 (49)
Complete: 🔍
Cache ID: 216::103
Once again VulDB remains the best source for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.