Siemens SCALANCE up to 4.4 Configuration resource consumption

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
3.9$0-$5k0.00

Summaryinfo

A vulnerability was found in Siemens SCALANCE up to 4.4. It has been rated as problematic. Affected by this issue is some unknown functionality of the component Configuration Handler. The manipulation leads to resource consumption. This vulnerability is uniquely identified as CVE-2023-44321. The attack is possible to be carried out remotely. No exploit exists. Upgrading the affected component is advised.

Detailsinfo

A vulnerability was found in Siemens SCALANCE up to 4.4 and classified as problematic. This issue affects an unknown function of the component Configuration Handler. The manipulation with an unknown input leads to a resource consumption vulnerability. Using CWE to declare the problem leads to CWE-400. The product does not properly control the allocation and maintenance of a limited resource, thereby enabling an actor to influence the amount of resources consumed, eventually leading to the exhaustion of available resources. Impacted is availability. The summary by CVE is:

A vulnerability has been identified in SCALANCE XB205-3 (SC, PN) (All versions < V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB205-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB205-3 (ST, PN) (All versions < V4.5), SCALANCE XB205-3LD (SC, E/IP) (All versions < V4.5), SCALANCE XB205-3LD (SC, PN) (All versions < V4.5), SCALANCE XB208 (E/IP) (All versions < V4.5), SCALANCE XB208 (PN) (All versions < V4.5), SCALANCE XB213-3 (SC, E/IP) (All versions < V4.5), SCALANCE XB213-3 (SC, PN) (All versions < V4.5), SCALANCE XB213-3 (ST, E/IP) (All versions < V4.5), SCALANCE XB213-3 (ST, PN) (All versions < V4.5), SCALANCE XB213-3LD (SC, E/IP) (All versions < V4.5), SCALANCE XB213-3LD (SC, PN) (All versions < V4.5), SCALANCE XB216 (E/IP) (All versions < V4.5), SCALANCE XB216 (PN) (All versions < V4.5), SCALANCE XC206-2 (SC) (All versions < V4.5), SCALANCE XC206-2 (ST/BFOC) (All versions < V4.5), SCALANCE XC206-2G PoE (All versions < V4.5), SCALANCE XC206-2G PoE (54 V DC) (All versions < V4.5), SCALANCE XC206-2G PoE EEC (54 V DC) (All versions < V4.5), SCALANCE XC206-2SFP (All versions < V4.5), SCALANCE XC206-2SFP EEC (All versions < V4.5), SCALANCE XC206-2SFP G (All versions < V4.5), SCALANCE XC206-2SFP G (EIP DEF.) (All versions < V4.5), SCALANCE XC206-2SFP G EEC (All versions < V4.5), SCALANCE XC208 (All versions < V4.5), SCALANCE XC208EEC (All versions < V4.5), SCALANCE XC208G (All versions < V4.5), SCALANCE XC208G (EIP def.) (All versions < V4.5), SCALANCE XC208G EEC (All versions < V4.5), SCALANCE XC208G PoE (All versions < V4.5), SCALANCE XC208G PoE (54 V DC) (All versions < V4.5), SCALANCE XC216 (All versions < V4.5), SCALANCE XC216-3G PoE (All versions < V4.5), SCALANCE XC216-3G PoE (54 V DC) (All versions < V4.5), SCALANCE XC216-4C (All versions < V4.5), SCALANCE XC216-4C G (All versions < V4.5), SCALANCE XC216-4C G (EIP Def.) (All versions < V4.5), SCALANCE XC216-4C G EEC (All versions < V4.5), SCALANCE XC216EEC (All versions < V4.5), SCALANCE XC224 (All versions < V4.5), SCALANCE XC224-4C G (All versions < V4.5), SCALANCE XC224-4C G (EIP Def.) (All versions < V4.5), SCALANCE XC224-4C G EEC (All versions < V4.5), SCALANCE XF204 (All versions < V4.5), SCALANCE XF204 DNA (All versions < V4.5), SCALANCE XF204-2BA (All versions < V4.5), SCALANCE XF204-2BA DNA (All versions < V4.5), SCALANCE XP208 (All versions < V4.5), SCALANCE XP208 (Ethernet/IP) (All versions < V4.5), SCALANCE XP208EEC (All versions < V4.5), SCALANCE XP208PoE EEC (All versions < V4.5), SCALANCE XP216 (All versions < V4.5), SCALANCE XP216 (Ethernet/IP) (All versions < V4.5), SCALANCE XP216EEC (All versions < V4.5), SCALANCE XP216POE EEC (All versions < V4.5), SCALANCE XR324WG (24 x FE, AC 230V) (All versions < V4.5), SCALANCE XR324WG (24 X FE, DC 24V) (All versions < V4.5), SCALANCE XR326-2C PoE WG (All versions < V4.5), SCALANCE XR326-2C PoE WG (without UL) (All versions < V4.5), SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions < V4.5), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (All versions < V4.5), SCALANCE XR328-4C WG (28xGE, AC 230V) (All versions < V4.5), SCALANCE XR328-4C WG (28xGE, DC 24V) (All versions < V4.5), SIPLUS NET SCALANCE XC206-2 (All versions < V4.5), SIPLUS NET SCALANCE XC206-2SFP (All versions < V4.5), SIPLUS NET SCALANCE XC208 (All versions < V4.5), SIPLUS NET SCALANCE XC216-4C (All versions < V4.5). Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.

The weakness was disclosed 11/14/2023 as ssa-699386. It is possible to read the advisory at cert-portal.siemens.com. The identification of this vulnerability is CVE-2023-44321 since 09/28/2023. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1499 according to MITRE ATT&CK.

Upgrading to version 4.5 eliminates this vulnerability.

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Productinfo

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 4.0
VulDB Meta Temp Score: 3.9

VulDB Base Score: 2.7
VulDB Temp Score: 2.6
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 6.5
NVD Vector: 🔍

CNA Base Score: 2.7
CNA Vector (Siemens AG): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Resource consumption
CWE: CWE-400 / CWE-404
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SCALANCE 4.5

Timelineinfo

09/28/2023 🔍
11/14/2023 +47 days 🔍
11/14/2023 +0 days 🔍
06/11/2024 +210 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-699386
Status: Confirmed

CVE: CVE-2023-44321 (🔍)
GCVE (CVE): GCVE-0-2023-44321
GCVE (VulDB): GCVE-100-245147

Entryinfo

Created: 11/14/2023 13:07
Updated: 06/11/2024 14:49
Changes: 11/14/2023 13:07 (51), 12/08/2023 09:50 (11), 06/11/2024 14:49 (15)
Complete: 🔍
Cache ID: 216::103