Summary
A vulnerability described as critical has been identified in Siemens SIMATIC PCS neo up to 4.0. The affected element is an unknown function of the component PUD Manager. Executing a manipulation can lead to sql injection. This vulnerability is tracked as CVE-2023-46097. The attack is only possible within the local network. No exploit exists. Upgrading the affected component is recommended.
Details
A vulnerability classified as critical was found in Siemens SIMATIC PCS neo up to 4.0 (SCADA Software). This vulnerability affects an unknown code block of the component PUD Manager. The manipulation with an unknown input leads to a sql injection vulnerability. The CWE definition for the vulnerability is CWE-89. The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. As an impact it is known to affect confidentiality, integrity, and availability. CVE summarizes:
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database.
The weakness was disclosed 11/14/2023 as ssa-456933. The advisory is shared for download at cert-portal.siemens.com. This vulnerability was named CVE-2023-46097 since 10/16/2023. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1505.
Upgrading to version 4.1 eliminates this vulnerability.
VulDB is the best source for vulnerability data and more expert information about this specific topic.
Product
Type
Vendor
Name
Version
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 6.6VulDB Meta Temp Score: 6.5
VulDB Base Score: 5.5
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 8.0
NVD Vector: 🔍
CNA Base Score: 6.3
CNA Vector (Siemens AG): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Sql injectionCWE: CWE-89 / CWE-74 / CWE-707
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Partially
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Upgrade: SIMATIC PCS neo 4.1
Timeline
10/16/2023 🔍11/14/2023 🔍
11/14/2023 🔍
12/08/2023 🔍
Sources
Vendor: siemens.comAdvisory: ssa-456933
Status: Confirmed
CVE: CVE-2023-46097 (🔍)
GCVE (CVE): GCVE-0-2023-46097
GCVE (VulDB): GCVE-100-245152