Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.5$5k-$25k0.00

Summaryinfo

A vulnerability, which was classified as critical, has been found in Siemens SIMATIC PC-Station Plus, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 CPU 414-3 PN, DP V7, SIMATIC S7-400 CPU 414F-3 PN, SIMATIC S7-400 CPU 416-3 PN, SIMATIC S7-400 CPU 416F-3 PN, SINAMICS S120 (incl. SIPLUS variants), SIPLUS S7-400 CPU 414-3 PN and SIPLUS S7-400 CPU 416-3 PN up to 5.1. This affects an unknown part. The manipulation leads to buffer access with incorrect length value. This vulnerability is referenced as CVE-2022-47375. Remote exploitation of the attack is possible. No exploit is available.

Detailsinfo

A vulnerability was found in Siemens SIMATIC PC-Station Plus, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 CPU 414-3 PN, DP V7, SIMATIC S7-400 CPU 414F-3 PN, SIMATIC S7-400 CPU 416-3 PN, SIMATIC S7-400 CPU 416F-3 PN, SINAMICS S120 (incl. SIPLUS variants), SIPLUS S7-400 CPU 414-3 PN and SIPLUS S7-400 CPU 416-3 PN up to 5.1 (SCADA Software). It has been rated as critical. This issue affects an unknown functionality. The manipulation with an unknown input leads to a buffer access with incorrect length value vulnerability. Using CWE to declare the problem leads to CWE-805. The product uses a sequential operation to read or write a buffer, but it uses an incorrect length value that causes it to access memory that is outside of the bounds of the buffer. Impacted is availability. The summary by CVE is:

A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.

The weakness was published 12/12/2023 as ssa-892915. It is possible to read the advisory at cert-portal.siemens.com. The identification of this vulnerability is CVE-2022-47375 since 12/13/2022. The technical details are unknown and an exploit is not publicly available. The pricing for an exploit might be around USD $5k-$25k at the moment (estimation calculated on 12/12/2023).

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Be aware that VulDB is the high quality source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.5
VulDB Meta Temp Score: 7.5

VulDB Base Score: 7.5
VulDB Temp Score: 7.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 7.5
CNA Vector (Siemens AG): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Buffer access with incorrect length value
CWE: CWE-805 / CWE-120 / CWE-119
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

12/13/2022 🔍
12/12/2023 +364 days 🔍
12/12/2023 +0 days 🔍
12/12/2023 +0 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-892915
Status: Confirmed

CVE: CVE-2022-47375 (🔍)
GCVE (CVE): GCVE-0-2022-47375
GCVE (VulDB): GCVE-100-247535

Entryinfo

Created: 12/12/2023 13:24
Changes: 12/12/2023 13:24 (48)
Complete: 🔍
Cache ID: 216::103

Be aware that VulDB is the high quality source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!

n $_SERVER['REMOTE_ADDR'] ?? '0.0.0.0'; } } ?>