Siemens Opcenter Quality buffer overflow

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.5$5k-$25k0.00

Summaryinfo

A vulnerability was found in Siemens Opcenter Quality, SIMATIC PCS neo, SINUMERIK Integrate RunMyHMI , Automotive and Totally Integrated Automation Portal. It has been rated as critical. This affects an unknown function. The manipulation leads to buffer overflow. This vulnerability is documented as CVE-2023-46283. The attack can be initiated remotely. There is not any exploit available.

Detailsinfo

A vulnerability was found in Siemens Opcenter Quality, SIMATIC PCS neo, SINUMERIK Integrate RunMyHMI , Automotive and Totally Integrated Automation Portal (Automation Software) and classified as critical. This issue affects an unknown function. The manipulation with an unknown input leads to a buffer overflow vulnerability. Using CWE to declare the problem leads to CWE-120. The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow. Impacted is availability. The summary by CVE is:

A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

The weakness was released 12/12/2023 as ssa-999588. The advisory is shared at cert-portal.siemens.com. The identification of this vulnerability is CVE-2023-46283 since 10/20/2023. Neither technical details nor an exploit are publicly available. The price for an exploit might be around USD $5k-$25k at the moment (estimation calculated on 08/13/2024).

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.5
VulDB Meta Temp Score: 7.5

VulDB Base Score: 7.5
VulDB Temp Score: 7.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 7.5
CNA Vector (Siemens AG): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Buffer overflow
CWE: CWE-120 / CWE-119
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

10/20/2023 🔍
12/12/2023 +53 days 🔍
12/12/2023 +0 days 🔍
08/13/2024 +245 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-999588
Status: Confirmed

CVE: CVE-2023-46283 (🔍)
GCVE (CVE): GCVE-0-2023-46283
GCVE (VulDB): GCVE-100-247541

Entryinfo

Created: 12/12/2023 13:27
Updated: 08/13/2024 11:36
Changes: 12/12/2023 13:27 (48), 08/13/2024 11:36 (16)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to know what is going to be exploited?

We predict KEV entries!