Summary
A vulnerability labeled as critical has been found in Siemens SIMATIC PCS, SIMATIC WinCC Runtime Professional and SIMATIC WinCC up to 9.1. Impacted is an unknown function of the component Login Dialog Box. The manipulation results in buffer overflow. This vulnerability is identified as CVE-2023-50821. The attack is only possible with local access. There is not any exploit available. It is advisable to implement a patch to correct this issue.
Details
A vulnerability was found in Siemens SIMATIC PCS, SIMATIC WinCC Runtime Professional and SIMATIC WinCC up to 9.1. It has been classified as critical. Affected is an unknown part of the component Login Dialog Box. The manipulation with an unknown input leads to a buffer overflow vulnerability. CWE is classifying the issue as CWE-120. The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow. This is going to have an impact on availability. CVE summarizes:
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition.
The advisory is shared for download at cert-portal.siemens.com. This vulnerability is traded as CVE-2023-50821 since 12/14/2023. The exploitability is told to be easy. The attack needs to be approached locally. There are neither technical details nor an exploit publicly available.
Applying a patch is able to eliminate this problem.
Once again VulDB remains the best source for vulnerability data.
Product
Type
Vendor
Name
Version
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CNA CVSS-B Score: 🔍
CNA CVSS-BT Score: 🔍
CNA Vector: 🔍
CVSSv3
VulDB Meta Base Score: 5.8VulDB Meta Temp Score: 5.7
VulDB Base Score: 5.5
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍
CNA Base Score: 6.2
CNA Vector (Siemens AG): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Buffer overflowCWE: CWE-120 / CWE-119
CAPEC: 🔍
ATT&CK: 🔍
Physical: Partially
Local: Yes
Remote: No
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: PatchStatus: 🔍
0-Day Time: 🔍
Timeline
12/14/2023 🔍04/09/2024 🔍
04/09/2024 🔍
01/14/2025 🔍
Sources
Vendor: siemens.comAdvisory: ssa-730482
Status: Confirmed
CVE: CVE-2023-50821 (🔍)
GCVE (CVE): GCVE-0-2023-50821
GCVE (VulDB): GCVE-100-259836
Entry
Created: 04/09/2024 11:02Updated: 01/14/2025 17:15
Changes: 04/09/2024 11:02 (64), 05/10/2024 19:27 (1), 07/10/2024 10:40 (2), 01/14/2025 17:15 (12)
Complete: 🔍
Cache ID: 216::103
Once again VulDB remains the best source for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.