Siemens RUGGEDCOM RM1224 LTE(4G) EU up to 8.0 2FA Token log file

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.7$0-$5k0.00

Summaryinfo

A vulnerability was found in Siemens RUGGEDCOM RM1224 LTE(4G) EU, RUGGEDCOM RM1224 LTE(4G) NAM, SCALANCE M804PB, SCALANCE M812-1 ADSL-Router family, SCALANCE M816-1 ADSL-Router family, SCALANCE M826-2 SHDSL-Router, SCALANCE M874-2, SCALANCE M874-3, SCALANCE M874-3 3G-Router (CN), SCALANCE M876-3, SCALANCE M876-3 (ROK), SCALANCE M876-4, SCALANCE M876-4 (EU), SCALANCE M876-4 (NAM), SCALANCE MUM853-1 (A1), SCALANCE MUM853-1 (B1), SCALANCE MUM853-1 (EU), SCALANCE MUM856-1 (A1), SCALANCE MUM856-1 (B1), SCALANCE MUM856-1 (CN), SCALANCE MUM856-1 (EU), SCALANCE MUM856-1 (RoW), SCALANCE S615 EEC LAN-Router and SCALANCE S615 LAN-Router up to 8.0 and classified as problematic. The impacted element is an unknown function of the component 2FA Token Handler. Such manipulation leads to log file. This vulnerability is uniquely identified as CVE-2024-41978. The attack can be launched remotely. No exploit exists. It is suggested to upgrade the affected component.

Detailsinfo

A vulnerability was found in Siemens RUGGEDCOM RM1224 LTE(4G) EU, RUGGEDCOM RM1224 LTE(4G) NAM, SCALANCE M804PB, SCALANCE M812-1 ADSL-Router family, SCALANCE M816-1 ADSL-Router family, SCALANCE M826-2 SHDSL-Router, SCALANCE M874-2, SCALANCE M874-3, SCALANCE M874-3 3G-Router (CN), SCALANCE M876-3, SCALANCE M876-3 (ROK), SCALANCE M876-4, SCALANCE M876-4 (EU), SCALANCE M876-4 (NAM), SCALANCE MUM853-1 (A1), SCALANCE MUM853-1 (B1), SCALANCE MUM853-1 (EU), SCALANCE MUM856-1 (A1), SCALANCE MUM856-1 (B1), SCALANCE MUM856-1 (CN), SCALANCE MUM856-1 (EU), SCALANCE MUM856-1 (RoW), SCALANCE S615 EEC LAN-Router and SCALANCE S615 LAN-Router up to 8.0. It has been rated as problematic. Affected by this issue is an unknown code of the component 2FA Token Handler. The manipulation with an unknown input leads to a log file vulnerability. Using CWE to declare the problem leads to CWE-532. Information written to log files can be of a sensitive nature and give valuable guidance to an attacker or expose sensitive user information. Impacted is confidentiality. CVE summarizes:

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices insert sensitive information about the generation of 2FA tokens into log files. This could allow an authenticated remote attacker to forge 2FA tokens of other users.

The advisory is shared for download at cert-portal.siemens.com. This vulnerability is handled as CVE-2024-41978 since 07/25/2024. The exploitation is known to be easy. The attack may be launched remotely. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1592.

Upgrading to version 8.1 eliminates this vulnerability.

Once again VulDB remains the best source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔍
CNA CVSS-BT Score: 🔍
CNA Vector: 🔍

CVSSv3info

VulDB Meta Base Score: 5.8
VulDB Meta Temp Score: 5.7

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 6.5
NVD Vector: 🔍

CNA Base Score: 6.5
CNA Vector (siemens): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Log file
CWE: CWE-532 / CWE-200 / CWE-284
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: RUGGEDCOM RM1224 LTE(4G) EU/RUGGEDCOM RM1224 LTE(4G) NAM/SCALANCE M804PB/SCALANCE M812-1 ADSL-Router family/SCALANCE M816-1 ADSL-Router family/SCALANCE M826-2 SHDSL-Router/SCALANCE M874-2/SCALANCE M874-3/SCALANCE M874-3 3G-Router (CN)/SCALANCE M876-3/SCALANCE M876-3 (ROK)/SCALANCE M876-4/SCALANCE M876-4 (EU)/SCALANCE M876-4 (NAM)/SCALANCE MUM853-1 (A1)/SCALANCE MUM853-1 (B1)/SCALANCE MUM853-1 (EU)/SCALANCE MUM856-1 (A1)/SCALANCE MUM856-1 (B1)/SCALANCE MUM856-1 (CN)/SCALANCE MUM856-1 (EU)/SCALANCE MUM856-1 (RoW)/SCALANCE S615 EEC LAN-Router/SCALANCE S615 LAN-Router 8.1

Timelineinfo

07/25/2024 🔍
08/13/2024 +19 days 🔍
08/13/2024 +0 days 🔍
08/24/2024 +11 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-087301
Status: Confirmed

CVE: CVE-2024-41978 (🔍)
GCVE (CVE): GCVE-0-2024-41978
GCVE (VulDB): GCVE-100-274292

Entryinfo

Created: 08/13/2024 10:30
Updated: 08/24/2024 07:47
Changes: 08/13/2024 10:30 (78), 08/24/2024 07:47 (12)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to know what is going to be exploited?

We predict KEV entries!