Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications missing access control
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 4.6 | $0-$5k | 0.00 |
Summary
A vulnerability was found in Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications and Dario Application Database and Internet-based Server Infrastructure and classified as problematic. The impacted element is an unknown function. The manipulation results in missing access control. This vulnerability was named CVE-2025-24843. The attack needs to be approached locally. There is no available exploit. It is suggested to upgrade the affected component.
Details
A vulnerability classified as problematic has been found in Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications and Dario Application Database and Internet-based Server Infrastructure. Affected is an unknown code. The manipulation with an unknown input leads to a missing access control vulnerability. CWE is classifying the issue as CWE-921. The product stores sensitive information in a file system or device that does not have built-in access control. This is going to have an impact on integrity, and availability. CVE summarizes:
Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data.
The weakness was presented by Noah Cutler and Manuel Del Rio as icsma-25-058-01. The advisory is shared for download at cisa.gov. This vulnerability is traded as CVE-2025-24843 since 01/27/2025. The exploitability is told to be easy. The attack needs to be approached locally. There are neither technical details nor an exploit publicly available.
Upgrading to version 5.8.7.0.36 eliminates this vulnerability.
VulDB is the best source for vulnerability data and more expert information about this specific topic.
Product
Type
Vendor
Name
- Dario Application Database and Internet-based Server Infrastructure
- USB-C Blood Glucose Monitoring System Starter Kit Android Applications
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CNA CVSS-B Score: 🔍
CNA CVSS-BT Score: 🔍
CNA Vector: 🔍
CVSSv3
VulDB Meta Base Score: 4.7VulDB Meta Temp Score: 4.6
VulDB Base Score: 4.4
VulDB Temp Score: 4.2
VulDB Vector: 🔍
VulDB Reliability: 🔍
CNA Base Score: 5.1
CNA Vector (icscert): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Missing access controlCWE: CWE-921 / CWE-284 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍
Physical: Partially
Local: Yes
Remote: No
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔍
Upgrade: USB-C Blood Glucose Monitoring System Starter Kit Android Applications/Dario Application Database and Internet-based Server Infrastructure 5.8.7.0.36
Timeline
01/27/2025 🔍02/28/2025 🔍
02/28/2025 🔍
02/28/2025 🔍
Sources
Advisory: icsma-25-058-01Researcher: Noah Cutler, Manuel Del Rio
Status: Confirmed
CVE: CVE-2025-24843 (🔍)
GCVE (CVE): GCVE-0-2025-24843
GCVE (VulDB): GCVE-100-298008
Entry
Created: 02/28/2025 18:07Changes: 02/28/2025 18:07 (76)
Complete: 🔍
Cache ID: 216::103
VulDB is the best source for vulnerability data and more expert information about this specific topic.
No comments yet. Languages: en.
Please log in to comment.