Siemens APOGEE PXC+TALON TC BACnet Broadcast Message expected behavior violation
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 4.5 | $0-$5k | 0.00 |
Summary
A vulnerability was found in Siemens APOGEE PXC+TALON TC. It has been classified as problematic. This affects an unknown part of the component BACnet Broadcast Message Handler. Performing a manipulation results in expected behavior violation. This vulnerability is reported as CVE-2025-40555. The attacker must have access to the local network to execute the attack. No exploit exists.
Details
A vulnerability was found in Siemens APOGEE PXC+TALON TC (unknown version). It has been classified as problematic. This affects an unknown code block of the component BACnet Broadcast Message Handler. The manipulation with an unknown input leads to a expected behavior violation vulnerability. CWE is classifying the issue as CWE-440. A feature, API, or function does not perform according to its specification. This is going to have an impact on availability. The summary by CVE is:
A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation.
It is possible to read the advisory at cert-portal.siemens.com. This vulnerability is uniquely identified as CVE-2025-40555 since 04/16/2025. The exploitability is told to be easy. Access to the local network is required for this attack. No form of authentication is needed for exploitation. The technical details are unknown and an exploit is not publicly available. The pricing for an exploit might be around USD $0-$5k at the moment (estimation calculated on 05/13/2025).
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
Be aware that VulDB is the high quality source for vulnerability data.
Product
Vendor
Name
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CNA CVSS-B Score: 🔍
CNA CVSS-BT Score: 🔍
CNA Vector: 🔍
CVSSv3
VulDB Meta Base Score: 4.5VulDB Meta Temp Score: 4.5
VulDB Base Score: 4.3
VulDB Temp Score: 4.3
VulDB Vector: 🔍
VulDB Reliability: 🔍
CNA Base Score: 4.7
CNA Vector (siemens): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Expected behavior violationCWE: CWE-440 / CWE-436
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Partially
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
Timeline
04/16/2025 🔍05/13/2025 🔍
05/13/2025 🔍
05/13/2025 🔍
Sources
Vendor: siemens.comAdvisory: ssa-718393
Status: Confirmed
CVE: CVE-2025-40555 (🔍)
GCVE (CVE): GCVE-0-2025-40555
GCVE (VulDB): GCVE-100-308607
Entry
Created: 05/13/2025 12:47Changes: 05/13/2025 12:47 (73)
Complete: 🔍
Cache ID: 216::103
Be aware that VulDB is the high quality source for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.