| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 9.8 | $5k-$25k | 0.00 |
Summary
A vulnerability was found in Siemens Energy Services. It has been declared as critical. Affected by this issue is some unknown functionality of the component G5DFR. Executing a manipulation can lead to default permission. The identification of this vulnerability is CVE-2025-40585. The attack may be launched remotely. There is no exploit available.
Details
A vulnerability was found in Siemens Energy Services (version now known). It has been declared as very critical. This vulnerability affects some unknown processing of the component G5DFR. The manipulation with an unknown input leads to a default permission vulnerability. The CWE definition for the vulnerability is CWE-276. During installation, installed file permissions are set to allow anyone to modify those files. As an impact it is known to affect confidentiality, integrity, and availability. CVE summarizes:
A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device.
The advisory is shared for download at cert-portal.siemens.com. This vulnerability was named CVE-2025-40585 since 04/16/2025. The exploitation appears to be easy. The attack can be initiated remotely. No form of authentication is required for a successful exploitation. There are neither technical details nor an exploit publicly available. The current price for an exploit might be approx. USD $5k-$25k (estimation calculated on 06/10/2025). The MITRE ATT&CK project declares the attack technique as T1222.
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2025-17678). Once again VulDB remains the best source for vulnerability data.
Product
Vendor
Name
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CNA CVSS-B Score: 🔍
CNA CVSS-BT Score: 🔍
CNA Vector: 🔍
CVSSv3
VulDB Meta Base Score: 9.9VulDB Meta Temp Score: 9.9
VulDB Base Score: 9.8
VulDB Temp Score: 9.8
VulDB Vector: 🔍
VulDB Reliability: 🔍
CNA Base Score: 9.9
CNA Vector (siemens): 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
Exploiting
Class: Default permissionCWE: CWE-276 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
Timeline
04/16/2025 🔍06/10/2025 🔍
06/10/2025 🔍
06/10/2025 🔍
Sources
Vendor: siemens.comAdvisory: ssa-345750
Status: Confirmed
CVE: CVE-2025-40585 (🔍)
GCVE (CVE): GCVE-0-2025-40585
GCVE (VulDB): GCVE-100-311884
EUVD: 🔍
Entry
Created: 06/10/2025 17:49Updated: 06/10/2025 18:58
Changes: 06/10/2025 17:49 (74), 06/10/2025 18:58 (1)
Complete: 🔍
Cache ID: 216::103
Once again VulDB remains the best source for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.