Siemens SCALANCE XRM334 up to 3.0 privileges management

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.2$0-$5k0.00

Summaryinfo

A vulnerability identified as critical has been detected in Siemens RUGGEDCOM RST2428P, SCALANCE XC316-8, SCALANCE XC324-4, SCALANCE XC324-4 EEC, SCALANCE XC332, SCALANCE XC416-8, SCALANCE XC424-4, SCALANCE XC432, SCALANCE XCH328, SCALANCE XCM324, SCALANCE XCM328, SCALANCE XCM332, SCALANCE XR302-32, SCALANCE XR322-12, SCALANCE XR326-8, SCALANCE XR326-8 EEC, SCALANCE XR502-32, SCALANCE XR522-12, SCALANCE XR526-8, SCALANCE XRH334 and SCALANCE XRM334 up to 3.0. This issue affects some unknown processing. This manipulation causes privileges management. This vulnerability is tracked as CVE-2024-41797. The attack is possible to be carried out remotely. No exploit exists. You should upgrade the affected component.

Detailsinfo

A vulnerability classified as critical was found in Siemens RUGGEDCOM RST2428P, SCALANCE XC316-8, SCALANCE XC324-4, SCALANCE XC324-4 EEC, SCALANCE XC332, SCALANCE XC416-8, SCALANCE XC424-4, SCALANCE XC432, SCALANCE XCH328, SCALANCE XCM324, SCALANCE XCM328, SCALANCE XCM332, SCALANCE XR302-32, SCALANCE XR322-12, SCALANCE XR326-8, SCALANCE XR326-8 EEC, SCALANCE XR502-32, SCALANCE XR522-12, SCALANCE XR526-8, SCALANCE XRH334 and SCALANCE XRM334 up to 3.0. Affected by this vulnerability is some unknown functionality. The manipulation with an unknown input leads to a privileges management vulnerability. The CWE definition for the vulnerability is CWE-269. The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.1), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.1), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.1), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.1), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.1), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.1), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.1), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.1), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.1), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.1), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.1), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.1), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.1), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.1), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.1), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.1), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.1), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.1), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.1), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.1), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.1), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.1), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.1), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.1), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.1), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.1), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.1), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.1), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.1), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.1), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.1), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.1), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.1), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.1), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.1), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.1), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.1), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.1), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.1), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.1), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.1). Affected devices contain an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to invoke an internal "do system" command which exceeds their privileges. This command allows the execution of certain low-risk actions, the most critical of which is clearing the local system log.

It is possible to read the advisory at cert-portal.siemens.com. This vulnerability is known as CVE-2024-41797 since 07/22/2024. The exploitation appears to be easy. The attack can be launched remotely. The technical details are unknown and an exploit is not publicly available. The pricing for an exploit might be around USD $0-$5k at the moment (estimation calculated on 06/10/2025). The attack technique deployed by this issue is T1068 according to MITRE ATT&CK.

Upgrading to version 3.1 eliminates this vulnerability.

Be aware that VulDB is the high quality source for vulnerability data.

Productinfo

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔍
CNA CVSS-BT Score: 🔍
CNA Vector: 🔍

CVSSv3info

VulDB Meta Base Score: 5.3
VulDB Meta Temp Score: 5.2

VulDB Base Score: 6.3
VulDB Temp Score: 6.0
VulDB Vector: 🔍
VulDB Reliability: 🔍

CNA Base Score: 4.3
CNA Vector (siemens): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Privileges management
CWE: CWE-269 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: RUGGEDCOM RST2428P/SCALANCE XC316-8/SCALANCE XC324-4/SCALANCE XC324-4 EEC/SCALANCE XC332/SCALANCE XC416-8/SCALANCE XC424-4/SCALANCE XC432/SCALANCE XCH328/SCALANCE XCM324/SCALANCE XCM328/SCALANCE XCM332/SCALANCE XR302-32/SCALANCE XR322-12/SCALANCE XR326-8/SCALANCE XR326-8 EEC/SCALANCE XR502-32/SCALANCE XR522-12/SCALANCE XR526-8/SCALANCE XRH334/SCALANCE XRM334 3.1

Timelineinfo

07/22/2024 🔍
06/10/2025 +323 days 🔍
06/10/2025 +0 days 🔍
06/10/2025 +0 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-633269
Status: Confirmed

CVE: CVE-2024-41797 (🔍)
GCVE (CVE): GCVE-0-2024-41797
GCVE (VulDB): GCVE-100-311887

Entryinfo

Created: 06/10/2025 17:49
Changes: 06/10/2025 17:49 (76)
Complete: 🔍
Cache ID: 216::103

Be aware that VulDB is the high quality source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!