Schneider Electric EcoStruxure IT Data Center Expert code injection

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.0$0-$5k0.00

Summaryinfo

A vulnerability classified as critical was found in Schneider Electric EcoStruxure IT Data Center Expert. Affected is an unknown function. Such manipulation leads to code injection. This vulnerability is documented as CVE-2025-50123. The attack can be executed remotely. There is not any exploit available. A patch should be applied to remediate this issue.

Detailsinfo

A vulnerability was found in Schneider Electric EcoStruxure IT Data Center Expert (version unknown). It has been rated as critical. Affected by this issue is an unknown function. The manipulation with an unknown input leads to a code injection vulnerability. Using CWE to declare the problem leads to CWE-94. The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment. Impacted is confidentiality, integrity, and availability. CVE summarizes:

CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote command execution by a privileged account when the server is accessed via a console and through exploitation of the hostname input.

The advisory is available at download.schneider-electric.com. This vulnerability is handled as CVE-2025-50123 since 06/12/2025. The exploitation is known to be easy. The attack may be launched remotely. The exploitation needs additional levels of successful authentication. The technical details are unknown and an exploit is not available. This vulnerability is assigned to T1059 by the MITRE ATT&CK project.

The vulnerability scanner Nessus provides a plugin with the ID 242985 (EcoStruxure IT Data Center Expert <= 8.3 Multiple Vulnerabilities (SEVD-2025-189-01)), which helps to determine the existence of the flaw in a target environment.

Applying a patch is able to eliminate this problem.

The vulnerability is also documented in the databases at Tenable (242985) and EUVD (EUVD-2025-21130). If you want to get best quality of vulnerability data, you may have to visit VulDB.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 7.2
VulDB Meta Temp Score: 7.1

VulDB Base Score: 7.2
VulDB Temp Score: 6.9
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 7.2
CNA Vector (schneider): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Code injection
CWE: CWE-94 / CWE-74 / CWE-707
CAPEC: 🔒
ATT&CK: 🔒

Physical: Yes
Local: Partially
Remote: Yes

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Nessus ID: 242985
Nessus Name: EcoStruxure IT Data Center Expert <= 8.3 Multiple Vulnerabilities (SEVD-2025-189-01)

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Patch
Status: 🔍

0-Day Time: 🔒

Timelineinfo

06/12/2025 CVE reserved
07/11/2025 +29 days Advisory disclosed
07/11/2025 +0 days VulDB entry created
07/30/2025 +19 days VulDB entry last update

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2025-189-01
Status: Confirmed

CVE: CVE-2025-50123 (🔒)
GCVE (CVE): GCVE-0-2025-50123
GCVE (VulDB): GCVE-100-316106
EUVD: 🔒

Entryinfo

Created: 07/11/2025 13:06
Updated: 07/30/2025 05:51
Changes: 07/11/2025 13:06 (75), 07/11/2025 13:45 (1), 07/14/2025 10:23 (1), 07/30/2025 05:51 (2)
Complete: 🔍
Cache ID: 216::103

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Interested in the pricing of exploits?

See the underground prices here!