Schneider Electric EcoStruxure Power Monitoring Expert TGML Diagram exposure of resource

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
4.2$0-$5k0.00

Summaryinfo

A vulnerability identified as problematic has been detected in Schneider Electric EcoStruxure Power Monitoring Expert and EcoStruxure Power Operation Advanced Reporting and Dashboards Module. This affects an unknown function of the component TGML Diagram Handler. The manipulation leads to exposure of resource. This vulnerability is referenced as CVE-2025-6788. Remote exploitation of the attack is possible. No exploit is available. To fix this issue, it is recommended to deploy a patch.

Detailsinfo

A vulnerability was found in Schneider Electric EcoStruxure Power Monitoring Expert and EcoStruxure Power Operation Advanced Reporting and Dashboards Module (affected version not known). It has been rated as problematic. This issue affects some unknown functionality of the component TGML Diagram Handler. The manipulation with an unknown input leads to a exposure of resource vulnerability. Using CWE to declare the problem leads to CWE-668. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. Impacted is confidentiality. The summary by CVE is:

CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources to the wrong control sphere, providing other authenticated users with potentially inappropriate access to TGML diagrams.

It is possible to read the advisory at download.schneider-electric.com. The identification of this vulnerability is CVE-2025-6788 since 06/27/2025. The exploitation is known to be easy. The attack may be initiated remotely. The technical details are unknown and an exploit is not publicly available.

Applying a patch is able to eliminate this problem.

The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2025-21131). Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 4.3
VulDB Meta Temp Score: 4.2

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 4.3
CNA Vector (schneider): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Exposure of resource
CWE: CWE-668 / CWE-200 / CWE-284
CAPEC: 🔒
ATT&CK: 🔒

Physical: No
Local: No
Remote: Yes

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Patch
Status: 🔍

0-Day Time: 🔒

Timelineinfo

06/27/2025 CVE reserved
07/11/2025 +14 days Advisory disclosed
07/11/2025 +0 days VulDB entry created
07/14/2025 +3 days VulDB entry last update

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2025-189-04
Status: Confirmed

CVE: CVE-2025-6788 (🔒)
GCVE (CVE): GCVE-0-2025-6788
GCVE (VulDB): GCVE-100-316115
EUVD: 🔒

Entryinfo

Created: 07/11/2025 13:38
Updated: 07/14/2025 10:23
Changes: 07/11/2025 13:38 (75), 07/11/2025 16:06 (1), 07/14/2025 10:23 (1)
Complete: 🔍
Cache ID: 216::103

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?