Rockwell Automation FactoryTalk Linx up to 6.49 process.env.NODE_ENV incorrect user management

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.1$0-$5k0.00

Summaryinfo

A vulnerability marked as problematic has been reported in Rockwell Automation FactoryTalk Linx up to 6.49. This affects an unknown function. Performing a manipulation of the argument process.env.NODE_ENV with the input development results in incorrect user management. This vulnerability was named CVE-2025-7972. The attack needs to be approached locally. There is no available exploit. It is suggested to upgrade the affected component.

Detailsinfo

A vulnerability was found in Rockwell Automation FactoryTalk Linx up to 6.49. It has been classified as problematic. This affects an unknown code. The manipulation of the argument process.env.NODE_ENV with the input value development leads to a incorrect user management vulnerability. CWE is classifying the issue as CWE-286. The product does not properly manage a user within its environment. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.

It is possible to read the advisory at rockwellautomation.com. This vulnerability is uniquely identified as CVE-2025-7972 since 07/21/2025. The exploitability is told to be easy. Attacking locally is a requirement. Technical details of the vulnerability are known, but there is no available exploit.

Upgrading to version 6.50 eliminates this vulnerability.

The vulnerability is also documented in the vulnerability database at CERT Bund (WID-SEC-2025-1849). Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Affected

  • Rockwell Automation FactoryTalk

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 7.2
VulDB Meta Temp Score: 7.1

VulDB Base Score: 5.3
VulDB Temp Score: 5.1
VulDB Vector: 🔒
VulDB Reliability: 🔍

NVD Base Score: 9.1
NVD Vector: 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Incorrect user management
CWE: CWE-286
CAPEC: 🔒
ATT&CK: 🔒

Physical: Partially
Local: Yes
Remote: Yes

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔒

Upgrade: FactoryTalk Linx 6.50

Timelineinfo

07/21/2025 CVE reserved
08/14/2025 +24 days Advisory disclosed
08/14/2025 +0 days VulDB entry created
10/29/2025 +76 days VulDB entry last update

Sourcesinfo

Advisory: rockwellautomation.com
Status: Confirmed

CVE: CVE-2025-7972 (🔒)
GCVE (CVE): GCVE-0-2025-7972
GCVE (VulDB): GCVE-100-320163
CERT Bund: WID-SEC-2025-1849 - Rockwell Automation FactoryTalk: Mehrere Schwachstellen

Entryinfo

Created: 08/14/2025 17:49
Updated: 10/29/2025 21:36
Changes: 08/14/2025 17:49 (68), 08/17/2025 01:51 (7), 10/29/2025 21:36 (12)
Complete: 🔍
Cache ID: 216::103

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you need the next level of professionalism?