Voltronic Power ViewPower/PowerShield Netguard Web Interface improper authentication

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.0$0-$5k0.00

Summaryinfo

A vulnerability marked as critical has been reported in Voltronic Power ViewPower and PowerShield Netguard. This vulnerability affects unknown code of the component Web Interface. This manipulation causes improper authentication. This vulnerability is registered as CVE-2022-43110. Remote exploitation of the attack is possible. No exploit is available. It is suggested to upgrade the affected component.

Detailsinfo

A vulnerability has been found in Voltronic Power ViewPower and PowerShield Netguard (the affected version is unknown) and classified as critical. Affected by this vulnerability is an unknown code of the component Web Interface. The manipulation with an unknown input leads to a improper authentication vulnerability. The CWE definition for the vulnerability is CWE-287. When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:

Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.

It is possible to read the advisory at ready2disclose.com. This vulnerability is known as CVE-2022-43110 since 10/17/2022. The exploitation appears to be easy. The attack can be launched remotely. The exploitation doesn't need any form of authentication. The technical details are unknown and an exploit is not publicly available.

Upgrading eliminates this vulnerability.

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Productinfo

Vendor

Name

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.3
VulDB Meta Temp Score: 7.0

VulDB Base Score: 7.3
VulDB Temp Score: 7.0
VulDB Vector: 🔒
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Improper authentication
CWE: CWE-287
CAPEC: 🔒
ATT&CK: 🔒

Physical: No
Local: No
Remote: Yes

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔒

Timelineinfo

10/17/2022 CVE reserved
08/22/2025 +1040 days Advisory disclosed
08/22/2025 +0 days VulDB entry created
08/22/2025 +0 days VulDB entry last update

Sourcesinfo

Advisory: ready2disclose.com
Status: Confirmed

CVE: CVE-2022-43110 (🔒)
GCVE (CVE): GCVE-0-2022-43110
GCVE (VulDB): GCVE-100-321115

Entryinfo

Created: 08/22/2025 23:38
Changes: 08/22/2025 23:38 (53)
Complete: 🔍
Cache ID: 216::103

Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!