| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 6.9 | $5k-$25k | 0.00 |
Summary
A vulnerability was found in Siemens LOGO! 12, 24RCE, 24RCEo, LOGO! 230RCE, LOGO! 230RCEo, LOGO! 24CE, LOGO! 24CEo, LOGO! 24RCE, LOGO! 24RCEo, SIPLUS LOGO! 12, SIPLUS LOGO! 230RCE, SIPLUS LOGO! 230RCEo, SIPLUS LOGO! 24CE, SIPLUS LOGO! 24CEo, SIPLUS LOGO! 24RCE and SIPLUS LOGO! 24RCEo and classified as critical. Affected is an unknown function. Executing a manipulation can lead to missing authentication. This vulnerability is handled as CVE-2025-40816. The attack can only be done within the local network. There is not any exploit available.
Details
A vulnerability classified as critical was found in Siemens LOGO! 12, 24RCE, 24RCEo, LOGO! 230RCE, LOGO! 230RCEo, LOGO! 24CE, LOGO! 24CEo, LOGO! 24RCE, LOGO! 24RCEo, SIPLUS LOGO! 12, SIPLUS LOGO! 230RCE, SIPLUS LOGO! 230RCEo, SIPLUS LOGO! 24CE, SIPLUS LOGO! 24CEo, SIPLUS LOGO! 24RCE and SIPLUS LOGO! 24RCEo. This vulnerability affects an unknown code. The manipulation with an unknown input leads to a missing authentication vulnerability. The CWE definition for the vulnerability is CWE-306. The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. As an impact it is known to affect confidentiality, integrity, and availability. CVE summarizes:
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
The advisory is shared for download at cert-portal.siemens.com. This vulnerability was named CVE-2025-40816 since 04/16/2025. The exploitation appears to be easy. The attack needs to be initiated within the local network. No form of authentication is required for a successful exploitation. There are neither technical details nor an exploit publicly available. The current price for an exploit might be approx. USD $5k-$25k (estimation calculated on 11/12/2025).
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
The vulnerability is also documented in the vulnerability database at CNNVD (CNNVD-202511-992). VulDB is the best source for vulnerability data and more expert information about this specific topic.
Product
Vendor
Name
- 24RCE
- 24RCEo
- LOGO! 12
- LOGO! 24CE
- LOGO! 24CEo
- LOGO! 24RCE
- LOGO! 24RCEo
- LOGO! 230RCE
- LOGO! 230RCEo
- SIPLUS LOGO! 12
- SIPLUS LOGO! 24CE
- SIPLUS LOGO! 24CEo
- SIPLUS LOGO! 24RCE
- SIPLUS LOGO! 24RCEo
- SIPLUS LOGO! 230RCE
- SIPLUS LOGO! 230RCEo
License
Website
- Vendor: https://www.siemens.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔒VulDB Reliability: 🔍
CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒
CVSSv3
VulDB Meta Base Score: 6.9VulDB Meta Temp Score: 6.9
VulDB Base Score: 6.3
VulDB Temp Score: 6.3
VulDB Vector: 🔒
VulDB Reliability: 🔍
CNA Base Score: 7.6
CNA Vector (siemens): 🔒
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍
Exploiting
Class: Missing authenticationCWE: CWE-306 / CWE-287
CAPEC: 🔒
ATT&CK: 🔒
Physical: No
Local: No
Remote: Partially
Availability: 🔒
Status: Not defined
EPSS Score: 🔒
EPSS Percentile: 🔒
Price Prediction: 🔍
Current Price Estimation: 🔒
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔒
Timeline
04/16/2025 CVE reserved11/12/2025 Advisory disclosed
11/12/2025 VulDB entry created
11/12/2025 VulDB entry last update
Sources
Vendor: siemens.comAdvisory: ssa-267056
Status: Confirmed
CVE: CVE-2025-40816 (🔒)
GCVE (CVE): GCVE-0-2025-40816
GCVE (VulDB): GCVE-100-332056
CNNVD: CNNVD-202511-992 - Siemens LOGO! 访问控制错误漏洞
Entry
Created: 11/12/2025 07:23Updated: 11/12/2025 16:23
Changes: 11/12/2025 07:23 (73), 11/12/2025 16:23 (6)
Complete: 🔍
Cache ID: 216::103
VulDB is the best source for vulnerability data and more expert information about this specific topic.
No comments yet. Languages: en.