Rockwellautomation Studio 5000 Logix Designer 30.01.00 FactoryTalk Activation Service unquoted search path

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.1$0-$5k0.00

Summaryinfo

A vulnerability was found in Rockwellautomation Studio 5000 Logix Designer 30.01.00. It has been rated as problematic. This impacts an unknown function of the file C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ of the component FactoryTalk Activation Service. Performing a manipulation results in unquoted search path. This vulnerability was named CVE-2019-25276. The attack needs to be approached locally. In addition, an exploit is available.

Detailsinfo

A vulnerability was found in Rockwellautomation Studio 5000 Logix Designer 30.01.00. It has been classified as critical. This affects an unknown function of the file C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ of the component FactoryTalk Activation Service. The manipulation with an unknown input leads to a unquoted search path vulnerability. CWE is classifying the issue as CWE-428. The product uses a search path that contains an unquoted element, in which the element contains whitespace or other separators. This can cause the product to access resources in a parent path. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.

The weakness was presented by Luis Martinez as 47676. It is possible to read the advisory at exploit-db.com. This vulnerability is uniquely identified as CVE-2019-25276 since 01/06/2026. The exploitability is told to be difficult. Attacking locally is a requirement. Technical details and a public exploit are known. The attack technique deployed by this issue is T1574.009 according to MITRE ATT&CK.

The exploit is shared for download at exploit-db.com. It is declared as proof-of-concept.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

The vulnerability is also documented in the databases at Exploit-DB (47676) and CNNVD (CNNVD-202602-886). Be aware that VulDB is the high quality source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 7.4
VulDB Meta Temp Score: 7.1

VulDB Base Score: 7.0
VulDB Temp Score: 6.4
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 7.8
CNA Vector (VulnCheck): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Unquoted search path
CWE: CWE-428 / CWE-426
CAPEC: 🔒
ATT&CK: 🔒

Physical: Partially
Local: Yes
Remote: No

Availability: 🔒
Access: Public
Status: Proof-of-Concept
Download: 🔒

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Exploit-DB: 🔒

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔒

Timelineinfo

01/06/2026 CVE reserved
02/05/2026 +30 days Advisory disclosed
02/05/2026 +0 days VulDB entry created
02/08/2026 +3 days VulDB entry last update

Sourcesinfo

Advisory: 47676
Researcher: Luis Martinez
Status: Not defined

CVE: CVE-2019-25276 (🔒)
GCVE (CVE): GCVE-0-2019-25276
GCVE (VulDB): GCVE-100-344463
CNNVD: CNNVD-202602-886 - Rockwell Automation Studio 5000 Logix Designer 代码问题漏洞

scip Labs: https://www.scip.ch/en/?labs.20161013

Entryinfo

Created: 02/05/2026 07:59
Updated: 02/08/2026 17:24
Changes: 02/05/2026 07:59 (82), 02/06/2026 16:16 (6), 02/07/2026 16:45 (1), 02/08/2026 17:24 (1)
Complete: 🔍
Cache ID: 216::103

Be aware that VulDB is the high quality source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you need the next level of professionalism?

Upgrade your account now!