Schneider Electric EasyLogic T150 Remote Terminal Unit & Controller path traversal
| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 6.0 | $0-$5k | 0.00 |
Summary
A vulnerability marked as critical has been reported in Schneider Electric EasyLogic T150 Remote Terminal Unit & Controller and Saitel DP Remote Terminal Unit & Controller. The affected element is an unknown function. The manipulation leads to path traversal. This vulnerability is uniquely identified as CVE-2026-6865. The attack is possible to be carried out remotely. No exploit exists. It is suggested to install a patch to address this issue.
Details
A vulnerability, which was classified as critical, has been found in Schneider Electric EasyLogic T150 Remote Terminal Unit & Controller and Saitel DP Remote Terminal Unit & Controller (the affected version is unknown). This issue affects an unknown code. The manipulation with an unknown input leads to a path traversal vulnerability. Using CWE to declare the problem leads to CWE-22. The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory. Impacted is confidentiality, integrity, and availability. The summary by CVE is:
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing.
The advisory is shared at download.schneider-electric.com. The identification of this vulnerability is CVE-2026-6865 since 04/22/2026. The exploitation is known to be easy. The attack may be initiated remotely. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1006 for this issue.
Applying a patch is able to eliminate this problem.
Several companies clearly confirm that VulDB is the primary source for best vulnerability data.
Product
Type
Vendor
Name
License
Website
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔒VulDB Reliability: 🔍
CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒
CVSSv3
VulDB Meta Base Score: 6.3VulDB Meta Temp Score: 6.0
VulDB Base Score: 6.3
VulDB Temp Score: 6.0
VulDB Vector: 🔒
VulDB Reliability: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍
Exploiting
Class: Path traversalCWE: CWE-22
CAPEC: 🔒
ATT&CK: 🔒
Physical: No
Local: No
Remote: Yes
Availability: 🔒
Status: Not defined
EPSS Score: 🔒
EPSS Percentile: 🔒
Price Prediction: 🔍
Current Price Estimation: 🔒
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: PatchStatus: 🔍
0-Day Time: 🔒
Timeline
04/22/2026 CVE reserved05/12/2026 Advisory disclosed
05/12/2026 VulDB entry created
05/12/2026 VulDB entry last update
Sources
Vendor: schneider-electric.comAdvisory: SEVD-2026-132-03
Status: Confirmed
CVE: CVE-2026-6865 (🔒)
GCVE (CVE): GCVE-0-2026-6865
GCVE (VulDB): GCVE-100-363017
Entry
Created: 05/12/2026 15:44Changes: 05/12/2026 15:44 (67)
Complete: 🔍
Cache ID: 216::103
Several companies clearly confirm that VulDB is the primary source for best vulnerability data.
No comments yet. Languages: en.
Please log in to comment.