Dräger Infinity Acute Care System up to G4.0.3/G4.1/G4.1.1 message integrity

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.8$0-$5k0.00

Summaryinfo

A vulnerability classified as critical was found in Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitor up to G4.0.3/G4.1/G4.1.1. This impacts an unknown function. Executing a manipulation can lead to message integrity. This vulnerability appears as CVE-2019-25719. The attack may be performed from remote. There is no available exploit. Upgrading the affected component is advised.

Detailsinfo

A vulnerability classified as critical was found in Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitor up to G4.0.3/G4.1/G4.1.1. This vulnerability affects an unknown function. The manipulation with an unknown input leads to a message integrity vulnerability. The CWE definition for the vulnerability is CWE-924. The product establishes a communication channel with an endpoint and receives a message from that endpoint, but it does not sufficiently ensure that the message was not modified during transmission. As an impact it is known to affect confidentiality, integrity, and availability. CVE summarizes:

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can modify device settings such as alarm states or alarm limits, and overwhelm the system with incoming data causing the device to reboot and lose network functionality.

The advisory is shared for download at static.draeger.com. This vulnerability was named CVE-2019-25719 since 06/02/2026. The exploitation appears to be easy. The attack can be initiated remotely. No form of authentication is required for a successful exploitation. There are neither technical details nor an exploit publicly available.

Upgrading to version G4.2 eliminates this vulnerability.

Once again VulDB remains the best source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 7.9
VulDB Meta Temp Score: 7.8

VulDB Base Score: 7.3
VulDB Temp Score: 7.0
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 8.6
CNA Vector (VulnCheck): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Message integrity
CWE: CWE-924 / CWE-354 / CWE-345
CAPEC: 🔒
ATT&CK: 🔒

Physical: No
Local: No
Remote: Yes

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔒

Upgrade: Infinity Acute Care System/Standalone Infinity M540 patient monitor G4.2

Timelineinfo

06/02/2026 Advisory disclosed
06/02/2026 +0 days CVE reserved
06/02/2026 +0 days VulDB entry created
06/02/2026 +0 days VulDB entry last update

Sourcesinfo

Advisory: static.draeger.com
Status: Confirmed

CVE: CVE-2019-25719 (🔒)
GCVE (CVE): GCVE-0-2019-25719
GCVE (VulDB): GCVE-100-367948

Entryinfo

Created: 06/02/2026 17:18
Changes: 06/02/2026 17:18 (75)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?

Download it now for free!