Dräger SC 6002XL/SC6802XL/SC 7000/SC8000/SC90000 XL up to G2.3.1 Device Configuration hard-coded credentials

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.9$0-$5k0.00

Summaryinfo

A vulnerability was found in Dräger SC 6002XL, SC6802XL, SC 7000, SC8000 and SC90000 XL up to G2.3.1. It has been rated as critical. This impacts an unknown function of the component Device Configuration Handler. Performing a manipulation results in hard-coded credentials. This vulnerability is known as CVE-2019-25722. Access to the local network is required for this attack. No exploit is available.

Detailsinfo

A vulnerability was found in Dräger SC 6002XL, SC6802XL, SC 7000, SC8000 and SC90000 XL up to G2.3.1. It has been classified as critical. This affects an unknown function of the component Device Configuration Handler. The manipulation with an unknown input leads to a hard-coded credentials vulnerability. CWE is classifying the issue as CWE-798. The product contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with direct device access can use the hard-coded credentials to access service and clinical accounts and alter device configuration, while a remote attacker can send malformed network packets to cause repeated device reboots, ultimately resulting in loss of network connectivity and disruption of patient monitoring.

The weakness was published by Jeroen Slobbe and Max Grim. The advisory is shared at static.draeger.com. This vulnerability is uniquely identified as CVE-2019-25722 since 06/02/2026. The exploitability is told to be easy. The attack needs to approached within the local network. No form of authentication is needed for exploitation. Neither technical details nor an exploit are publicly available. The price for an exploit might be around USD $0-$5k at the moment (estimation calculated on 06/03/2026). MITRE ATT&CK project uses the attack technique T1110.001 for this issue.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Productinfo

Type

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 6.9
VulDB Meta Temp Score: 6.9

VulDB Base Score: 6.3
VulDB Temp Score: 6.3
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 7.6
CNA Vector (VulnCheck): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Hard-coded credentials
CWE: CWE-798 / CWE-259 / CWE-255
CAPEC: 🔒
ATT&CK: 🔒

Physical: No
Local: No
Remote: Partially

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔒

Timelineinfo

06/02/2026 CVE reserved
06/02/2026 +0 days VulDB entry created
06/03/2026 +0 days Advisory disclosed
06/03/2026 +0 days VulDB entry last update

Sourcesinfo

Advisory: static.draeger.com
Researcher: Jeroen Slobbe, Max Grim
Status: Confirmed

CVE: CVE-2019-25722 (🔒)
GCVE (CVE): GCVE-0-2019-25722
GCVE (VulDB): GCVE-100-368025

Entryinfo

Created: 06/03/2026 01:27
Changes: 06/03/2026 01:27 (76)
Complete: 🔍
Cache ID: 216::103

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!