Dräger Zeus IE/Zeus RS C500 up to 1.0.4 USB Interface exposure of resource

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.4$0-$5k2.98

Summaryinfo

A vulnerability has been found in Dräger Zeus IE and Zeus RS C500 up to 1.0.4 and classified as problematic. The affected element is an unknown function of the component USB Interface. This manipulation causes exposure of resource. This vulnerability is tracked as CVE-2025-15653. It is feasible to perform the attack on the physical device. No exploit exists. The affected component should be upgraded.

Detailsinfo

A vulnerability has been found in Dräger Zeus IE and Zeus RS C500 up to 1.0.4 and classified as problematic. Affected by this vulnerability is an unknown part of the component USB Interface. The manipulation with an unknown input leads to a exposure of resource vulnerability. The CWE definition for the vulnerability is CWE-668. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:

Dräger Zeus Infinity Empowered (Zeus IE) and Zeus RS C500 anesthesia workstations contain a local security vulnerability that allows unauthorized individuals with physical access to compromise software integrity via USB interface manipulation. Attackers can exploit the unprotected USB interfaces to impair therapy functions, manipulate device-processed data, or leverage the device as a pivot point for broader network-based attacks when connected to a network or Dräger Service Connect.

The advisory is shared at draeger.com. This vulnerability is known as CVE-2025-15653 since 06/02/2026. The exploitation appears to be easy. An attack has to be approached locally. The exploitation doesn't need any form of authentication. Neither technical details nor an exploit are publicly available.

Upgrading to version 1.0.5 eliminates this vulnerability.

The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2025-210044). If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 5.5
VulDB Meta Temp Score: 5.4

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 6.8
CNA Vector (VulnCheck): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Exposure of resource
CWE: CWE-668 / CWE-200 / CWE-284
CAPEC: 🔒
ATT&CK: 🔒

Physical: Yes
Local: Yes
Remote: No

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔒

Upgrade: Zeus IE/Zeus RS C500 1.0.5

Timelineinfo

06/02/2026 CVE reserved
06/02/2026 +0 days VulDB entry created
06/03/2026 +0 days Advisory disclosed
06/04/2026 +1 days VulDB entry last update

Sourcesinfo

Advisory: draeger.com
Status: Confirmed

CVE: CVE-2025-15653 (🔒)
GCVE (CVE): GCVE-0-2025-15653
GCVE (VulDB): GCVE-100-368077
EUVD: 🔒

Entryinfo

Created: 06/03/2026 01:48
Updated: 06/04/2026 00:26
Changes: 06/03/2026 01:48 (76), 06/04/2026 00:26 (1)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Interested in the pricing of exploits?

See the underground prices here!