| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 7.0 | $0-$5k | 3.27- |
Summary
A vulnerability marked as critical has been reported in Softing smartLink HW-PN up to 1.9. This vulnerability affects unknown code. This manipulation causes memory leak. This vulnerability is handled as CVE-2026-13148. The attack can be initiated remotely. There is not any exploit available.
Details
A vulnerability has been found in Softing smartLink HW-PN up to 1.9 and classified as critical. Affected by this vulnerability is an unknown code. The manipulation with an unknown input leads to a memory leak vulnerability. The CWE definition for the vulnerability is CWE-401. The product does not sufficiently track and release allocated memory after it has been used, which slowly consumes remaining memory. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:
Missing release of memory after effective lifetime vulnerability in Softing smartLink allows resource leak exposure. This issue affects smartLink HW-PN: from 1.04 before 1.10.
It is possible to read the advisory at industrial.softing.com. This vulnerability is known as CVE-2026-13148 since 06/24/2026. The exploitation appears to be easy. The attack can be launched remotely. The exploitation doesn't need any form of authentication. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1499 according to MITRE ATT&CK.
Upgrading to version 1.10 eliminates this vulnerability.
The vulnerability is also documented in the vulnerability database at EUVD (EUVD-2026-70986). Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
Product
Vendor
Name
Version
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔒VulDB Reliability: 🔍
CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒
CVSSv3
VulDB Meta Base Score: 7.3VulDB Meta Temp Score: 7.0
VulDB Base Score: 7.3
VulDB Temp Score: 7.0
VulDB Vector: 🔒
VulDB Reliability: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍
Exploiting
Class: Memory leakCWE: CWE-401 / CWE-404
CAPEC: 🔒
ATT&CK: 🔒
Physical: No
Local: No
Remote: Yes
Availability: 🔒
Status: Not defined
EPSS Score: 🔒
EPSS Percentile: 🔒
Price Prediction: 🔍
Current Price Estimation: 🔒
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
0-Day Time: 🔒
Upgrade: smartLink HW-PN 1.10
Timeline
06/24/2026 CVE reserved09/04/2026 Advisory disclosed
09/04/2026 VulDB entry created
09/04/2026 VulDB entry last update
Sources
Advisory: industrial.softing.comStatus: Confirmed
CVE: CVE-2026-13148 (🔒)
GCVE (CVE): GCVE-0-2026-13148
GCVE (VulDB): GCVE-100-398731
EUVD: 🔒
Entry
Created: 09/04/2026 12:06Updated: 09/04/2026 13:30
Changes: 09/04/2026 12:06 (69), 09/04/2026 13:30 (1)
Complete: 🔍
Cache ID: 216::103
Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.