Mitsubishi Electric GX Works3/Motion Control Setting improper authentication

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
4.8$0-$5k2.01-

Summaryinfo

A vulnerability described as problematic has been identified in Mitsubishi Electric GX Works3 and Motion Control Setting. This affects an unknown function. Executing a manipulation can lead to improper authentication. This vulnerability appears as CVE-2026-15688. The attack requires local access. There is no available exploit.

Detailsinfo

A vulnerability was found in Mitsubishi Electric GX Works3 and Motion Control Setting (unknown version). It has been declared as problematic. This vulnerability affects an unknown code block. The manipulation with an unknown input leads to a improper authentication vulnerability. The CWE definition for the vulnerability is CWE-287. When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct. As an impact it is known to affect confidentiality, integrity, and availability. CVE summarizes:

Incorrect Implementation of Authentication Algorithm Vulnerability in Mitsubishi Electric GX Works3 and Motion Control Setting allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modifying part of the executable module in memory, and thereby may be able to view, tamper with, destroy, or delete control programs.

The advisory is shared for download at mitsubishielectric.com. This vulnerability was named CVE-2026-15688 since 07/14/2026. The exploitation appears to be easy. The attack needs to be approached locally. Successful exploitation requires user interaction by the victim. There are neither technical details nor an exploit publicly available.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

Once again VulDB remains the best source for vulnerability data.

Productinfo

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA CVSS-B Score: 🔒
CNA CVSS-BT Score: 🔒
CNA Vector: 🔒

CVSSv3info

VulDB Meta Base Score: 4.8
VulDB Meta Temp Score: 4.8

VulDB Base Score: 4.8
VulDB Temp Score: 4.8
VulDB Vector: 🔒
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Improper authentication
CWE: CWE-287
CAPEC: 🔒
ATT&CK: 🔒

Physical: Partially
Local: Yes
Remote: Partially

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔒

Timelineinfo

07/14/2026 CVE reserved
09/17/2026 +65 days Advisory disclosed
09/17/2026 +0 days VulDB entry created
09/17/2026 +0 days VulDB entry last update

Sourcesinfo

Advisory: mitsubishielectric.com
Status: Confirmed

CVE: CVE-2026-15688 (🔒)
GCVE (CVE): GCVE-0-2026-15688
GCVE (VulDB): GCVE-100-406348

Entryinfo

Created: 09/17/2026 10:50
Changes: 09/17/2026 10:50 (62)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?

Download it now for free!