VDB-62252 · CVE-2011-5163 · SA46779

Schneider Electric CitectSCADA 7.10 Login memory corruption

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.7$0-$5k0.00

Summaryinfo

A vulnerability categorized as problematic has been discovered in Schneider Electric CitectSCADA 7.10. This vulnerability affects unknown code of the component Login. Such manipulation leads to memory corruption. This vulnerability is uniquely identified as CVE-2011-5163. No exploit exists. It is advisable to upgrade the affected component.

Detailsinfo

A vulnerability was found in Schneider Electric CitectSCADA 7.10 (SCADA Software). It has been rated as problematic. Affected by this issue is an unknown functionality of the component Login. The manipulation with an unknown input leads to a memory corruption vulnerability. Using CWE to declare the problem leads to CWE-119. The product performs operations on a memory buffer, but it can read from or write to a memory location that is outside of the intended boundary of the buffer. Impacted is confidentiality, integrity, and availability. CVE summarizes:

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.

The weakness was disclosed 09/15/2012 (Website). The advisory is shared for download at us-cert.gov. This vulnerability is handled as CVE-2011-5163 since 09/15/2012. The exploitation is known to be easy. The attack needs to be approached locally. No form of authentication is required for exploitation. There are neither technical details nor an exploit publicly available.

Upgrading to version 7.10 eliminates this vulnerability.

The vulnerability is also documented in the databases at OSVDB (76937†), Secunia (SA46779†) and SecurityTracker (ID 1026306†). Once again VulDB remains the best source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.9
VulDB Meta Temp Score: 5.7

VulDB Base Score: 5.9
VulDB Temp Score: 5.7
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Memory corruption
CWE: CWE-119
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: No

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: CitectSCADA 7.10

Timelineinfo

11/09/2011 🔍
11/09/2011 +0 days 🔍
09/15/2012 +311 days 🔍
09/15/2012 +0 days 🔍
09/15/2012 +0 days 🔍
03/24/2015 +920 days 🔍
02/21/2019 +1430 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: us-cert.gov
Status: Confirmed
Confirmation: 🔍

CVE: CVE-2011-5163 (🔍)
GCVE (CVE): GCVE-0-2011-5163
GCVE (VulDB): GCVE-100-62252
Secunia: 46779 - Schneider Electric CitectSCADA Batch Server Login Buffer Overflow Vulnerability, Moderately Critical
OSVDB: 76937
SecurityTracker: 1026306

Entryinfo

Created: 03/24/2015 12:22
Updated: 02/21/2019 10:12
Changes: 03/24/2015 12:22 (51), 02/21/2019 10:12 (8)