C3-ilex EOScada 11.0.19.1 EOSCoreScada.exe access control

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.1$0-$5k0.00

Summaryinfo

A vulnerability was found in C3-ilex EOScada 11.0.19.1. It has been rated as problematic. Affected by this vulnerability is an unknown functionality of the file EOSCoreScada.exe. The manipulation leads to access control. This vulnerability is traded as CVE-2012-1810. There is no exploit available. Upgrading the affected component is advised.

Detailsinfo

A vulnerability was found in C3-ilex EOScada 11.0.19.1 (SCADA Software). It has been rated as problematic. This issue affects an unknown function of the file EOSCoreScada.exe. The manipulation with an unknown input leads to a access control vulnerability. Using CWE to declare the problem leads to CWE-264. Impacted is availability. The summary by CVE is:

EOSCoreScada.exe in C3-ilex EOScada before 11.0.19.2 allows remote attackers to cause a denial of service (daemon restart) by sending data to TCP port (1) 5050 or (2) 24004.

The weakness was shared 11/13/2012 by DiGiT (Website). The advisory is shared at us-cert.gov. The identification of this vulnerability is CVE-2012-1810 since 03/21/2012. The exploitation is known to be easy. The attack may be initiated remotely. No form of authentication is needed for a successful exploitation. Technical details are known, but no exploit is available. MITRE ATT&CK project uses the attack technique T1068 for this issue.

Upgrading to version 11.0.19.1 eliminates this vulnerability.

The vulnerability is also documented in the databases at X-Force (79753), SecurityFocus (BID 56364†) and Secunia (SA51171†). The entries VDB-62912, VDB-62911 and VDB-62910 are related to this item. If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Type

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.3
VulDB Meta Temp Score: 5.1

VulDB Base Score: 5.3
VulDB Temp Score: 5.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Access control
CWE: CWE-264
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: EOScada 11.0.19.1

Timelineinfo

03/21/2012 🔍
11/01/2012 +225 days 🔍
11/02/2012 +1 days 🔍
11/13/2012 +11 days 🔍
11/13/2012 +0 days 🔍
03/24/2015 +861 days 🔍
02/23/2019 +1432 days 🔍

Sourcesinfo

Advisory: us-cert.gov
Researcher: DiGiT
Status: Not defined

CVE: CVE-2012-1810 (🔍)
GCVE (CVE): GCVE-0-2012-1810
GCVE (VulDB): GCVE-100-62909
X-Force: 79753
SecurityFocus: 56364 - C3-ilex EOScada Multiple Security Vulnerabilities
Secunia: 51171 - EOScada Information Disclosure and Denial of Service Vulnerabilities, Less Critical

See also: 🔍

Entryinfo

Created: 03/24/2015 12:22
Updated: 02/23/2019 08:51
Changes: 03/24/2015 12:22 (59), 02/23/2019 08:51 (1)
Complete: 🔍
Cache ID: 216:7A4:103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?

Download it now for free!