Ecava IntegraXor 4.1.4360/4.1.4392 access control

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
8.6$0-$5k0.00

Summaryinfo

A vulnerability categorized as problematic has been discovered in Ecava IntegraXor 4.1.4360/4.1.4392. This issue affects some unknown processing. Such manipulation leads to access control. This vulnerability is referenced as CVE-2014-2375. No exploit is available.

Detailsinfo

A vulnerability was found in Ecava IntegraXor 4.1.4360/4.1.4392 (SCADA Software) and classified as critical. Affected by this issue is an unknown functionality. The manipulation with an unknown input leads to a access control vulnerability. Using CWE to declare the problem leads to CWE-264. Impacted is confidentiality, integrity, and availability. CVE summarizes:

Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to read or write to arbitrary files, and obtain sensitive information or cause a denial of service (disk consumption), via the CSV export feature.

The weakness was published 09/15/2014 by Andrea Micalizzi (Website). The advisory is shared for download at ics-cert.us-cert.gov. This vulnerability is handled as CVE-2014-2375 since 03/13/2014. The exploitation is known to be easy. The attack may be launched remotely. No form of authentication is required for exploitation. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1068.

The commercial vulnerability scanner Qualys is able to test this issue with plugin 122664 (Ecava Integraxor SCADA Server Multiple Vulnerabilities).

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

The vulnerability is also documented in the databases at X-Force (95952), EUVD (EUVD-2014-2412), SecurityFocus (BID 69767†) and Vulnerability Center (SBV-46303†). Similar entries are available at VDB-71242 and VDB-71241. VulDB is the best source for vulnerability data and more expert information about this specific topic.

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 8.6
VulDB Meta Temp Score: 8.6

VulDB Base Score: 8.6
VulDB Temp Score: 8.6
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Access control
CWE: CWE-264
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Qualys ID: 🔍
Qualys Name: 🔍

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

03/13/2014 🔍
09/11/2014 +182 days 🔍
09/11/2014 +0 days 🔍
09/15/2014 +4 days 🔍
09/15/2014 +0 days 🔍
09/30/2014 +15 days 🔍
03/26/2015 +177 days 🔍
10/14/2025 +3855 days 🔍

Sourcesinfo

Advisory: ics-cert.us-cert.gov
Researcher: Andrea Micalizzi
Status: Not defined

CVE: CVE-2014-2375 (🔍)
GCVE (CVE): GCVE-0-2014-2375
GCVE (VulDB): GCVE-100-71240
EUVD: 🔍
X-Force: 95952
SecurityFocus: 69767 - Ecava Integraxor SCADA Server CVE-2014-2375 Arbitrary File Read and Write Vulnerability
Vulnerability Center: 46303 - Ecava IntegraXor SCADA Server 4.1.4392 and Earlier Remote Read\\Write Access to Files and DoS via the CSV Export Feature, High

See also: 🔍

Entryinfo

Created: 03/26/2015 15:08
Updated: 10/14/2025 04:09
Changes: 03/26/2015 15:08 (57), 06/07/2017 19:57 (4), 10/14/2025 01:29 (24), 10/14/2025 04:09 (1)
Complete: 🔍
Cache ID: 216::103

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Interested in the pricing of exploits?