| CVSS Meta Temp Score | Current Exploit Price (≈) | CTI Interest Score |
|---|---|---|
| 4.0 | $0-$5k | 0.00 |
Summary
A vulnerability marked as problematic has been reported in EMC NetWorker up to 3.0. Affected by this vulnerability is an unknown functionality. Performing a manipulation results in information disclosure. This vulnerability is cataloged as CVE-2014-4620. There is no exploit available.
Details
A vulnerability was found in EMC NetWorker up to 3.0. It has been classified as problematic. This affects an unknown code. The manipulation with an unknown input leads to a information disclosure vulnerability. CWE is classifying the issue as CWE-200. The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information. This is going to have an impact on confidentiality. The summary by CVE is:
The EMC NetWorker Module for MEDITECH (aka NMMEDI) 3.0 build 87 through 90, when EMC RecoverPoint and Plink are used, stores cleartext RecoverPoint Appliance credentials in nsrmedisv.raw log files, which allows local users to obtain sensitive information by reading these files.
The weakness was shared 10/25/2014 (Website). It is possible to read the advisory at xforce.iss.net. This vulnerability is uniquely identified as CVE-2014-4620 since 06/24/2014. The exploitability is told to be easy. Attacking locally is a requirement. No form of authentication is needed for exploitation. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1592 according to MITRE ATT&CK.
The vulnerability scanner Nessus provides a plugin with the ID 78823 (EMC NetWorker Module for MEDITECH 3.0 Build 87 - 90 Local Information Disclosure), which helps to determine the existence of the flaw in a target environment. It is assigned to the family Windows.
There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.
The vulnerability is also documented in the databases at X-Force (97756), Tenable (78823), SecurityFocus (BID 70726†), Secunia (SA61952†) and Vulnerability Center (SBV-46975†). Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
Product
Vendor
Name
Version
License
Website
- Vendor: https://www.dellemc.com/
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 4.0VulDB Meta Temp Score: 4.0
VulDB Base Score: 4.0
VulDB Temp Score: 4.0
VulDB Vector: 🔍
VulDB Reliability: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Information disclosureCWE: CWE-200 / CWE-284 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍
Physical: Partially
Local: Yes
Remote: No
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Nessus ID: 78823
Nessus Name: EMC NetWorker Module for MEDITECH 3.0 Build 87 - 90 Local Information Disclosure
Nessus File: 🔍
Nessus Risk: 🔍
Nessus Family: 🔍
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: no mitigation knownStatus: 🔍
0-Day Time: 🔍
Timeline
06/24/2014 🔍10/22/2014 🔍
10/22/2014 🔍
10/25/2014 🔍
10/25/2014 🔍
10/27/2014 🔍
11/03/2014 🔍
11/11/2014 🔍
03/27/2015 🔍
04/03/2022 🔍
Sources
Vendor: dellemc.comAdvisory: 128841
Status: Not defined
CVE: CVE-2014-4620 (🔍)
GCVE (CVE): GCVE-0-2014-4620
GCVE (VulDB): GCVE-100-72699
X-Force: 97756
SecurityFocus: 70726 - EMC NetWorker Module for MEDITECH CVE-2014-4620 Local Information Disclosure Vulnerability
Secunia: 61952 - EMC NetWorker Module for Meditech Credentials Logging Security Issue, Not Critical
SecurityTracker: 1031116
Vulnerability Center: 46975 - EMC NetWorker Module for MEDITECH Local Information Disclosure via nsrmedisv.raw Log Files, Low
Entry
Created: 03/27/2015 12:07Updated: 04/03/2022 07:31
Changes: 03/27/2015 12:07 (59), 06/11/2017 05:23 (5), 04/03/2022 07:26 (4), 04/03/2022 07:31 (1)
Complete: 🔍
Cache ID: 216::103
Statistical analysis made it clear that VulDB provides the best quality for vulnerability data.
No comments yet. Languages: en.
Please log in to comment.