Siemens RUGGEDCOM ROX I Integrated Web Server Reflected cross site scripting

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
5.1$0-$5k0.00

Summaryinfo

A vulnerability identified as problematic has been detected in Siemens RUGGEDCOM ROX I. The affected element is an unknown function of the component Integrated Web Server. The manipulation leads to cross site scripting (Reflected). This vulnerability is uniquely identified as CVE-2017-2687. The attack is possible to be carried out remotely. No exploit exists. It is recommended to apply restrictive firewalling.

Detailsinfo

A vulnerability was found in Siemens RUGGEDCOM ROX I (affected version not known). It has been rated as problematic. This issue affects some unknown functionality of the component Integrated Web Server. The manipulation with an unknown input leads to a cross site scripting vulnerability (Reflected). Using CWE to declare the problem leads to CWE-79. The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. Impacted is integrity. The summary by CVE is:

Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link.

The bug was discovered 03/28/2017. The weakness was disclosed 03/29/2017 by Maxim Rupp (Website). The advisory is shared at siemens.com. The identification of this vulnerability is CVE-2017-2687 since 12/01/2016. The attack may be initiated remotely. No form of authentication is needed for a successful exploitation. It demands that the victim is doing some kind of user interaction. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1059.007 for this issue.

Addressing this vulnerability is possible by firewalling tcp/10000.

The vulnerability is also documented in the vulnerability database at SecurityFocus (BID 97170†). The entries VDB-99016, VDB-99018, VDB-99019 and VDB-99020 are pretty similar. Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Productinfo

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.2
VulDB Meta Temp Score: 5.1

VulDB Base Score: 4.3
VulDB Temp Score: 4.2
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 6.1
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Name: Reflected
Class: Cross site scripting / Reflected
CWE: CWE-79 / CWE-94 / CWE-74
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Firewall
Status: 🔍

0-Day Time: 🔍

Firewalling: 🔍

Timelineinfo

12/01/2016 🔍
03/28/2017 +117 days 🔍
03/28/2017 +0 days 🔍
03/28/2017 +0 days 🔍
03/29/2017 +1 days 🔍
03/29/2017 +0 days 🔍
11/22/2022 +2064 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-327980
Researcher: Maxim Rupp
Status: Not defined
Confirmation: 🔍

CVE: CVE-2017-2687 (🔍)
GCVE (CVE): GCVE-0-2017-2687
GCVE (VulDB): GCVE-100-99017
SecurityFocus: 97170 - Siemens RUGGEDCOM ROX I ICSA-17-087-01 Multiple Security Vulnerabilities
OSVDB: - CVE-2017-2687 - Siemens - RUGGEDCOM ROX I - Cross-Site Scripting Issue
SecurityTracker: 1038160

See also: 🔍

Entryinfo

Created: 03/29/2017 10:48
Updated: 11/22/2022 20:56
Changes: 03/29/2017 10:48 (60), 09/15/2020 07:04 (6), 11/22/2022 20:56 (4)
Complete: 🔍
Cache ID: 216::103

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!