VDB-99361 · CVE-2017-7574 · BID 97518

Schneider Electric SoMachine Basic/Modicon TM221CE16R Project Protection Feature XML File Password hard-coded credentials

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
8.4$0-$5k0.00

Summaryinfo

A vulnerability has been found in Schneider Electric SoMachine Basic and Modicon TM221CE16R and classified as critical. This impacts an unknown function of the component Project Protection Feature. This manipulation as part of XML File causes hard-coded credentials (Password). This vulnerability is handled as CVE-2017-7574. The attack can be initiated remotely. There is not any exploit available.

Detailsinfo

A vulnerability classified as critical was found in Schneider Electric SoMachine Basic and Modicon TM221CE16R (SCADA Software) (the affected version unknown). Affected by this vulnerability is an unknown part of the component Project Protection Feature. The manipulation as part of a XML File leads to a hard-coded credentials vulnerability (Password). The CWE definition for the vulnerability is CWE-798. The product contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. As an impact it is known to affect confidentiality. The summary by CVE is:

Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.

The bug was discovered 04/13/2017. The weakness was released 04/06/2017 by Ralf Spenneberg (Website). The advisory is shared at download.schneider-electric.com. This vulnerability is known as CVE-2017-7574 since 04/06/2017. The exploitation appears to be easy. The attack can be launched remotely. The exploitation doesn't need any form of authentication. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1110.001 for this issue.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

The vulnerability is also documented in the vulnerability database at SecurityFocus (BID 97518†). Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Productinfo

Type

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 8.4
VulDB Meta Temp Score: 8.4

VulDB Base Score: 5.3
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 9.8
NVD Vector: 🔍

ADP CISA Base Score: 10.0
ADP CISA Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Name: Password
Class: Hard-coded credentials / Password
CWE: CWE-798 / CWE-259 / CWE-255
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

04/06/2017 🔍
04/06/2017 +0 days 🔍
04/06/2017 +0 days 🔍
04/06/2017 +0 days 🔍
04/07/2017 +1 days 🔍
04/13/2017 +6 days 🔍
05/29/2026 +3333 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: download.schneider-electric.com
Researcher: Ralf Spenneberg
Status: Not defined
Confirmation: 🔍

CVE: CVE-2017-7574 (🔍)
GCVE (CVE): GCVE-0-2017-7574
GCVE (VulDB): GCVE-100-99361
SecurityFocus: 97518 - Schneider Electric SoMachine and Modicon CVE-2017-7574 Security Bypass Vulnerability
OSVDB: - CVE-2017-7574 - Schneider Electric - Multiple Products - Hardcoded Key Issue

Entryinfo

Created: 04/07/2017 09:08
Updated: 05/29/2026 21:38
Changes: 04/07/2017 09:08 (60), 08/26/2020 15:59 (6), 05/29/2026 21:38 (28)
Complete: 🔍
Cache ID: 216::103

Several companies clearly confirm that VulDB is the primary source for best vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!