Medtronic Vulnerabilità

Sequenza temporale

Genere

Prodotto

Medtronic Valleylab FT10 Energy Platform4
Medtronic Smart Model 25000 Patient Reader3
Medtronic CareLink 2090 Programmer3
Medtronic 2090 Carelink Programmer3
Medtronic Valleylab Exchange Client2

Contromisure

Official Fix4
Temporary Fix0
Workaround1
Unavailable1
Not Defined20

Sfruttabilità

High0
Functional0
Proof-of-Concept0
Unproven1
Not Defined25

Accesso al vettore

Not Defined0
Physical11
Local4
Adjacent6
Network5

Autenticazione

Not Defined0
High0
Low4
None22

Interazione dell'utente

Not Defined0
Required3
None23

C3BM Index

CVSSv3 Base

≤10
≤20
≤31
≤41
≤57
≤69
≤73
≤82
≤91
≤102

CVSSv3 Temp

≤10
≤20
≤31
≤41
≤57
≤69
≤73
≤82
≤91
≤102

VulDB

≤10
≤20
≤32
≤43
≤512
≤63
≤70
≤83
≤91
≤102

NVD

≤10
≤20
≤30
≤40
≤55
≤64
≤76
≤84
≤92
≤100

CNA

≤10
≤20
≤30
≤40
≤50
≤60
≤71
≤80
≤90
≤101

Fornitore

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

Research

≤10
≤20
≤30
≤40
≤50
≤60
≤70
≤80
≤90
≤100

Exploiter 0 giorni

<1k13
<2k9
<5k2
<10k0
<25k1
<50k1
<100k0
≥100k0

Exploiter aujourd'hui

<1k23
<2k0
<5k2
<10k0
<25k0
<50k1
<100k0
≥100k0

Sfrutta il volume del mercato

🔴 CTI Attività

Affected Products (60): 2090 Carelink Programmer (3), 8840 N'Vision Clinician Programmer (2), 8870 N'Vision Removable Application Card (2), 24950 MyCareLink Monitor (2), 24952 MyCareLink Monitor (2), Amplia CRT-D (2), CareLink 2090 Programmer (3), CareLink 9790 Programmer 29901 (1), CareLink Monitor (2), Claria CRT-D (2), Compia CRT-D (2), Concerto CRT-D (2), Consulta CRT-D (2), Evera ICD (2), InsterStim Applications (1), MMT 508 (2), MMT 522 (2), MMT 523 (2), MMT 523K (2), MMT 530G (2), MMT 551 (2), MMT 722 (2), MMT 723 (2), MMT 723K (2), MMT 751 (2), Maximo II CRT-D (2), Maximo II ICD (2), MinMed 508 (1), MiniMed 620G (1), MiniMed 630G (1), MiniMed 640G (1), MiniMed 670G (1), MiniMed Paradigm 515 (1), MiniMed Paradigm 522 (1), MiniMed Paradigm 522K (1), MiniMed Paradigm 523 (1), MiniMed Paradigm 712E (1), MiniMed Paradigm 715 (1), MiniMed Paradigm 722 (1), MiniMed Paradigm 722K (1), MiniMed Paradigm 723 (1), Minimed Paradigm 512 (1), Minimed Paradigm 712 (1), Mirro ICD (2), MyCareLink 24950 (2), MyCareLink 24952 (2), MyCareLink Monitor (2), MyCareLink Patient Monitor (2), Nayamed ND ICD (2), Paceart Optima (1), Paradigm wireless insulin pump (1), Primo ICD (2), Protecta CRT-D (2), Protecta ICD (2), Secura ICD (2), Smart Model 25000 Patient Reader (3), Valleylab Exchange Client (2), Valleylab FT10 Energy Platform (4), Valleylab FX8 Energy Platform (2), Valleylab LS10 Energy Platform (2)

Data di pubblicazioneBaseTempVulnerabilitàProdSfrConEPSSCTICVE
29/06/20239.59.5Medtronic Paceart Optima Microsoft Messaging Queuing Service escalazione di privilegiSconosciutoNot DefinedNot Defined0.000530.03CVE-2023-31222
01/03/20235.85.8Medtronic InsterStim Applications autenticazione deboleSconosciutoNot DefinedOfficial Fix0.000540.00CVE-2023-25931
24/09/20222.92.9Medtronic MiniMed 620G escalazione di privilegiSconosciutoNot DefinedWorkaround0.000420.04CVE-2022-32537
13/12/20209.69.2Medtronic Smart Model 25000 Patient Reader Update System race conditionMedical Device SoftwareNot DefinedOfficial Fix0.003120.00CVE-2020-27252
13/12/20208.88.4Medtronic Smart Model 25000 Patient Reader Debug Command buffer overflowMedical Device SoftwareNot DefinedOfficial Fix0.005440.00CVE-2020-25187
13/12/20205.55.3Medtronic Smart Model 25000 Patient Reader App Authentication autenticazione deboleMedical Device SoftwareNot DefinedOfficial Fix0.000650.00CVE-2020-25183
08/11/20197.47.4Medtronic Valleylab Exchange Client autenticazione deboleMedical Device SoftwareNot DefinedNot Defined0.001620.03CVE-2019-13543
08/11/20195.55.5Medtronic Valleylab Exchange Client Password Hashing escalazione di privilegiMedical Device SoftwareNot DefinedNot Defined0.000440.02CVE-2019-13539
08/11/20193.33.3Medtronic Valleylab LS10 Energy Platform RFID escalazione di privilegiMedical Device SoftwareNot DefinedNot Defined0.000670.00CVE-2019-13535
08/11/20194.44.4Medtronic Valleylab LS10 Energy Platform RFID autenticazione deboleMedical Device SoftwareNot DefinedNot Defined0.000550.00CVE-2019-13531

16 non vengono visualizzate più voci