Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.1$0-$5k0.00

Summaryinfo

A vulnerability was found in Hospira LifeCare PCA Infusion System. It has been rated as critical. This affects an unknown part. The manipulation leads to information disclosure. This vulnerability is uniquely identified as CVE-2015-1012. The attack is possible to be carried out remotely. No exploit exists. Upgrading the affected component is advised.

Detailsinfo

A vulnerability, which was classified as critical, has been found in Hospira LifeCare PCA Infusion System (Medical Device Software) (version unknown). This issue affects an unknown function. The manipulation with an unknown input leads to a information disclosure vulnerability. Using CWE to declare the problem leads to CWE-200. The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information. Impacted is confidentiality, integrity, and availability. The summary by CVE is:

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access.

The bug was discovered 06/10/2015. The weakness was disclosed 03/25/2019 (Website). It is possible to read the advisory at ics-cert.us-cert.gov. The identification of this vulnerability is CVE-2015-1012 since 01/10/2015. The exploitation is known to be easy. The attack may be initiated remotely. No form of authentication is needed for a successful exploitation. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1592 according to MITRE ATT&CK.

The vulnerability was handled as a non-public zero-day exploit for at least 1384 days. During that time the estimated underground price was around $0-$5k.

Upgrading eliminates this vulnerability.

The entry VDB-76305 is pretty similar. Be aware that VulDB is the high quality source for vulnerability data.

Productinfo

Type

Vendor

Name

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.4
VulDB Meta Temp Score: 7.2

VulDB Base Score: 7.3
VulDB Temp Score: 7.0
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.5
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Researcher Base Score: 🔍
NVD Base Score: 🔍

Exploitinginfo

Class: Information disclosure
CWE: CWE-200 / CWE-284 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/10/2015 🔍
06/10/2015 +151 days 🔍
03/25/2019 +1384 days 🔍
03/26/2019 +1 days 🔍
05/19/2020 +420 days 🔍

Sourcesinfo

Advisory: ics-cert.us-cert.gov
Status: Not defined

CVE: CVE-2015-1012 (🔍)
GCVE (CVE): GCVE-0-2015-1012
GCVE (VulDB): GCVE-100-132167
See also: 🔍

Entryinfo

Created: 03/26/2019 10:07
Updated: 05/19/2020 16:36
Changes: 03/26/2019 10:07 (63), 05/19/2020 16:36 (1)
Complete: 🔍
Cache ID: 216::103

Be aware that VulDB is the high quality source for vulnerability data.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you know our Splunk app?

Download it now for free!