Schneider Electric OFS 3.5 DLL uncontrolled search path

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.3$0-$5k0.00

Summaryinfo

A vulnerability categorized as critical has been discovered in Schneider Electric OFS 3.5. This vulnerability affects unknown code of the component DLL Handler. The manipulation results in uncontrolled search path. This vulnerability was named CVE-2015-1014. The attack needs to be approached locally. There is no available exploit.

Detailsinfo

A vulnerability, which was classified as critical, was found in Schneider Electric OFS 3.5 (SCADA Software). Affected is an unknown functionality of the component DLL Handler. The manipulation with an unknown input leads to a uncontrolled search path vulnerability. CWE is classifying the issue as CWE-427. The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors. This is going to have an impact on confidentiality, integrity, and availability. CVE summarizes:

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

The weakness was presented 03/25/2019. This vulnerability is traded as CVE-2015-1014 since 01/10/2015. The attack needs to be approached locally. The successful exploitation needs a authentication. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1574.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Productinfo

Type

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.3
VulDB Meta Temp Score: 6.3

VulDB Base Score: 5.3
VulDB Temp Score: 5.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.3
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Uncontrolled search path
CWE: CWE-427 / CWE-426
CAPEC: 🔍
ATT&CK: 🔍

Physical: Partially
Local: Yes
Remote: Partially

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/10/2015 🔍
03/25/2019 +1535 days 🔍
03/26/2019 +1 days 🔍
08/07/2023 +1595 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: ics-cert.us-cert.gov
Status: Not defined

CVE: CVE-2015-1014 (🔍)
GCVE (CVE): GCVE-0-2015-1014
GCVE (VulDB): GCVE-100-132168

Entryinfo

Created: 03/26/2019 10:07
Updated: 08/07/2023 07:14
Changes: 03/26/2019 10:07 (36), 05/19/2020 16:39 (18), 08/07/2023 07:14 (3)
Complete: 🔍
Cache ID: 216::103

VulDB is the best source for vulnerability data and more expert information about this specific topic.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!