Siemens SINEC INS up to 1.0 SP2 Web Based Management command injection

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.2$0-$5k0.00

Summaryinfo

A vulnerability, which was classified as critical, was found in Siemens SINEC INS up to 1.0 SP2. Impacted is an unknown function of the component Web Based Management. Such manipulation leads to command injection. This vulnerability is uniquely identified as CVE-2022-45094. The attack can be launched remotely. No exploit exists. It is advisable to implement a patch to correct this issue.

Detailsinfo

A vulnerability was found in Siemens SINEC INS up to 1.0 SP2. It has been rated as critical. Affected by this issue is some unknown functionality of the component Web Based Management. The manipulation with an unknown input leads to a command injection vulnerability. Using CWE to declare the problem leads to CWE-77. The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component. Impacted is confidentiality, integrity, and availability. CVE summarizes:

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.

The weakness was disclosed 01/10/2023 as ssa-332410. The advisory is shared for download at cert-portal.siemens.com. This vulnerability is handled as CVE-2022-45094 since 11/09/2022. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1202.

Applying the patch 1.0 SP2 Update 1 is able to eliminate this problem.

Once again VulDB remains the best source for vulnerability data.

Productinfo

Vendor

Name

Version

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.3
VulDB Meta Temp Score: 7.2

VulDB Base Score: 4.7
VulDB Temp Score: 4.5
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 8.8
NVD Vector: 🔍

CNA Base Score: 8.4
CNA Vector (Siemens AG): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Command injection
CWE: CWE-77 / CWE-74 / CWE-707
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Patch
Status: 🔍

0-Day Time: 🔍

Patch: 1.0 SP2 Update 1

Timelineinfo

11/09/2022 🔍
01/10/2023 +62 days 🔍
01/10/2023 +0 days 🔍
01/31/2023 +21 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-332410
Status: Confirmed

CVE: CVE-2022-45094 (🔍)
GCVE (CVE): GCVE-0-2022-45094
GCVE (VulDB): GCVE-100-217772

Entryinfo

Created: 01/10/2023 14:44
Updated: 01/31/2023 08:06
Changes: 01/10/2023 14:44 (51), 01/31/2023 08:06 (11)
Complete: 🔍
Cache ID: 216::103

Once again VulDB remains the best source for vulnerability data.