PTZOptics PT30X-SDI/PT30X-NDI up to 6.3.39 Authorization Header /cgi-bin/param.cgi improper authentication

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
8.4$0-$5k0.00

Summaryinfo

A vulnerability identified as critical has been detected in PTZOptics PT30X-SDI and PT30X-NDI up to 6.3.39. This vulnerability affects unknown code of the file /cgi-bin/param.cgi of the component Authorization Header Handler. Performing a manipulation results in improper authentication. This vulnerability is reported as CVE-2024-8956. The attack is possible to be carried out remotely. Moreover, an exploit is present. You should upgrade the affected component.

Detailsinfo

A vulnerability, which was classified as critical, was found in PTZOptics PT30X-SDI and PT30X-NDI up to 6.3.39. This affects some unknown functionality of the file /cgi-bin/param.cgi of the component Authorization Header Handler. The manipulation with an unknown input leads to a improper authentication vulnerability. CWE is classifying the issue as CWE-287. When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.

The weakness was disclosed by Konstantin Lazarev. The advisory is shared at ptzoptics.com. This vulnerability is uniquely identified as CVE-2024-8956 since 09/17/2024. The exploitability is told to be easy. It is possible to initiate the attack remotely. No form of authentication is needed for exploitation. Technical details and a exploit are known.

It is declared as attacked. The vulnerability scanner Nessus provides a plugin with the ID 210334 (PTZOptics Camera Multiple Vulnerabilities (Direct Check)), which helps to determine the existence of the flaw in a target environment. The CISA Known Exploited Vulnerabilities Catalog lists this issue since 11/04/2024 with a due date of 11/25/2024:

Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

Upgrading to version 6.3.40 eliminates this vulnerability. The upgrade is hosted for download at ptzoptics.com.

The vulnerability is also documented in the databases at Tenable (210334) and EUVD (EUVD-2024-49505). If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Productinfo

Vendor

Name

Version

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 8.5
VulDB Meta Temp Score: 8.4

VulDB Base Score: 7.3
VulDB Temp Score: 7.0
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 9.1
NVD Vector: 🔍

CNA Base Score: 9.1
CNA Vector (VulnCheck): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Improper authentication
CWE: CWE-287
CAPEC: 🔍
ATT&CK: 🔍

Physical: No
Local: No
Remote: Yes

Availability: 🔍
Status: Attacked

EPSS Score: 🔍
EPSS Percentile: 🔍

KEV Added: 🔍
KEV Due: 🔍
KEV Remediation: 🔍
KEV Ransomware: 🔍
KEV Notice: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Nessus ID: 210334
Nessus Name: PTZOptics Camera Multiple Vulnerabilities (Direct Check)

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: PT30X-SDI/PT30X-NDI 6.3.40

Timelineinfo

09/17/2024 🔍
09/17/2024 +0 days 🔍
09/17/2024 +0 days 🔍
11/22/2025 +431 days 🔍

Sourcesinfo

Advisory: ptzoptics.com
Researcher: Konstantin Lazarev
Status: Confirmed

CVE: CVE-2024-8956 (🔍)
GCVE (CVE): GCVE-0-2024-8956
GCVE (VulDB): GCVE-100-277797
EUVD: 🔍
scip Labs: https://www.scip.ch/en/?labs.20161013

Entryinfo

Created: 09/17/2024 23:03
Updated: 11/22/2025 14:45
Changes: 09/17/2024 23:03 (67), 09/21/2024 06:48 (1), 10/01/2024 18:34 (11), 11/05/2024 00:11 (13), 11/05/2024 19:38 (2), 11/22/2025 14:45 (1)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to stay up to date on a daily basis?

Enable the mail alert feature now!