Dell PowerProtect Data Domain DDSH CLI os command injection

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
6.7$5k-$25k0.00

Summaryinfo

A vulnerability marked as critical has been reported in Dell PowerProtect Data Domain. Affected by this issue is some unknown functionality of the component DDSH CLI. Performing a manipulation results in os command injection. This vulnerability was named CVE-2025-30097. The attack needs to be approached locally. There is no available exploit.

Detailsinfo

A vulnerability, which was classified as critical, was found in Dell PowerProtect Data Domain (the affected version is unknown). This affects an unknown code of the component DDSH CLI. The manipulation with an unknown input leads to a os command injection vulnerability. CWE is classifying the issue as CWE-78. The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.1.0.10, LTS2024 release Versions 7.13.1.0 through 7.13.1.25, LTS 2023 release versions 7.10.1.0 through 7.10.1.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the DDSH CLI. A high privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges

The advisory is shared at dell.com. This vulnerability is uniquely identified as CVE-2025-30097 since 03/17/2025. The exploitability is told to be easy. An attack has to be approached locally. Additional levels of successful authentication are necessary for exploitation. Neither technical details nor an exploit are publicly available. The price for an exploit might be around USD $5k-$25k at the moment (estimation calculated on 09/27/2025). MITRE ATT&CK project uses the attack technique T1202 for this issue.

The vulnerability scanner Nessus provides a plugin with the ID 265948 (Dell Data Domain OS Command Injection (DSA-2025-159)), which helps to determine the existence of the flaw in a target environment.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

The vulnerability is also documented in the databases at Tenable (265948) and CERT Bund (WID-SEC-2025-1714). If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Affected

  • Dell PowerProtect Data Domain

Productinfo

Vendor

Name

License

Website

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔒
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 6.7
VulDB Meta Temp Score: 6.7

VulDB Base Score: 6.7
VulDB Temp Score: 6.7
VulDB Vector: 🔒
VulDB Reliability: 🔍

CNA Base Score: 6.7
CNA Vector (dell): 🔒

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock
UnlockUnlockUnlockUnlockUnlockUnlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfo

Class: Os command injection
CWE: CWE-78 / CWE-77 / CWE-74
CAPEC: 🔒
ATT&CK: 🔒

Physical: Partially
Local: Yes
Remote: No

Availability: 🔒
Status: Not defined

EPSS Score: 🔒
EPSS Percentile: 🔒

Price Prediction: 🔍
Current Price Estimation: 🔒

0-DayUnlockUnlockUnlockUnlock
TodayUnlockUnlockUnlockUnlock

Nessus ID: 265948
Nessus Name: Dell Data Domain OS Command Injection (DSA-2025-159)

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔒

Timelineinfo

03/17/2025 CVE reserved
08/04/2025 +139 days Advisory disclosed
08/04/2025 +0 days VulDB entry created
09/27/2025 +54 days VulDB entry last update

Sourcesinfo

Vendor: dell.com

Advisory: dsa-2025-159
Status: Confirmed

CVE: CVE-2025-30097 (🔒)
GCVE (CVE): GCVE-0-2025-30097
GCVE (VulDB): GCVE-100-318693
CERT Bund: WID-SEC-2025-1714 - Dell PowerProtect Data Domain: Mehrere Schwachstellen

Entryinfo

Created: 08/04/2025 17:37
Updated: 09/27/2025 17:07
Changes: 08/04/2025 17:37 (62), 08/05/2025 16:27 (7), 08/05/2025 16:43 (1), 09/27/2025 17:07 (2)
Complete: 🔍
Cache ID: 216::103

If you want to get the best quality for vulnerability data then you always have to consider VulDB.

Discussion

No comments yet. Languages: en.

Please log in to comment.

Want to stay up to date on a daily basis?

Enable the mail alert feature now!