A vulnerability identified as problematic has been detected in Schneider Electric PowerLogic PM8ECC up to 2.650 on PowerMeter 800. This issue affects some unknown processing. Performing a manipulation results in cross site scripting. This vulnerability is known as CVE-2016-4513. Remote exploitation of the attack is possible. No exploit is available. You should upgrade the affected component.
Details
A vulnerability was found in Schneider Electric PowerLogic PM8ECC up to 2.650 on PowerMeter 800 (SCADA Software). It has been classified as problematic. This affects some unknown functionality. The manipulation with an unknown input leads to a cross site scripting vulnerability. CWE is classifying the issue as CWE-79. The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. This is going to have an impact on confidentiality, and integrity. The summary by CVE is:
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
The weakness was published 06/26/2016 (Website). The advisory is shared at ics-cert.us-cert.gov. This vulnerability is uniquely identified as CVE-2016-4513 since 05/05/2016. The exploitability is told to be easy. It is possible to initiate the attack remotely. No form of authentication is needed for exploitation. It demands that the victim is doing some kind of user interaction. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1059.007 for this issue.
Upgrading to version 2.651 eliminates this vulnerability.
If you want to get the best quality for vulnerability data then you always have to consider VulDB.
Product
Type
Vendor
Name
Version
License
Website
CPE 2.3
CPE 2.2
CVSSv4
VulDB Vector: 🔍VulDB Reliability: 🔍
CVSSv3
VulDB Meta Base Score: 6.1VulDB Meta Temp Score: 5.9
VulDB Base Score: 6.1
VulDB Temp Score: 5.8
VulDB Vector: 🔍
VulDB Reliability: 🔍
NVD Base Score: 6.1
NVD Vector: 🔍
CVSSv2
| AV | AC | Au | C | I | A |
|---|---|---|---|---|---|
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| 💳 | 💳 | 💳 | 💳 | 💳 | 💳 |
| Vector | Complexity | Authentication | Confidentiality | Integrity | Availability |
|---|---|---|---|---|---|
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
| Unlock | Unlock | Unlock | Unlock | Unlock | Unlock |
VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍
NVD Base Score: 🔍
Exploiting
Class: Cross site scriptingCWE: CWE-79 / CWE-94 / CWE-74
CAPEC: 🔍
ATT&CK: 🔍
Physical: No
Local: No
Remote: Yes
Availability: 🔍
Status: Not defined
EPSS Score: 🔍
EPSS Percentile: 🔍
Price Prediction: 🔍
Current Price Estimation: 🔍
| 0-Day | Unlock | Unlock | Unlock | Unlock |
|---|---|---|---|---|
| Today | Unlock | Unlock | Unlock | Unlock |
Threat Intelligence
Interest: 🔍Active Actors: 🔍
Active APT Groups: 🔍
Countermeasures
Recommended: UpgradeStatus: 🔍
Upgrade: PowerLogic PM8ECC 2.651
Timeline
05/05/2016 🔍06/25/2016 🔍
06/26/2016 🔍
06/27/2016 🔍
02/09/2019 🔍
Sources
Vendor: schneider-electric.comAdvisory: ics-cert.us-cert.gov
Status: Not defined
CVE: CVE-2016-4513 (🔍)
GCVE (CVE): GCVE-0-2016-4513
GCVE (VulDB): GCVE-100-88125
Entry
Created: 06/27/2016 09:08Updated: 02/09/2019 11:19
Changes: 06/27/2016 09:08 (49), 02/09/2019 11:19 (9)
Complete: 🔍
Cache ID: 216::103
If you want to get the best quality for vulnerability data then you always have to consider VulDB.
No comments yet. Languages: en.
Please log in to comment.