Siemens SIMATIC Step 7 up to 15.x Password Hash information disclosure

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
4.9$0-$5k0.00

A vulnerability was found in Siemens SIMATIC Step 7 up to 15.x (SCADA Software). It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Password Hash. The manipulation with an unknown input leads to a information disclosure vulnerability. The CWE definition for the vulnerability is CWE-200. The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information. As an impact it is known to affect confidentiality, integrity, and availability. The summary by CVE is:

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.

The bug was discovered 11/13/2018. The weakness was presented 12/13/2018 (Website). The advisory is shared at cert-portal.siemens.com. This vulnerability is known as CVE-2018-13811 since 07/10/2018. The exploitation appears to be difficult. An attack has to be approached locally. The exploitation doesn't need any form of authentication. Neither technical details nor an exploit are publicly available. MITRE ATT&CK project uses the attack technique T1592 for this issue.

The vulnerability was handled as a non-public zero-day exploit for at least 30 days. During that time the estimated underground price was around $0-$5k.

Upgrading to version 15.1 eliminates this vulnerability.

See VDB-101525, VDB-108257, VDB-109954 and VDB-111694 for similar entries.

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 5.0
VulDB Meta Temp Score: 4.9

VulDB Base Score: 4.5
VulDB Temp Score: 4.3
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 5.5
NVD Vector: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

NVD Base Score: 🔍

Exploitinginfo

Class: Information disclosure
CWE: CWE-200 / CWE-284 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Local: Yes
Remote: No

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: SIMATIC Step 7 15.1

Timelineinfo

07/10/2018 🔍
11/13/2018 +126 days 🔍
11/13/2018 +0 days 🔍
12/13/2018 +30 days 🔍
12/13/2018 +0 days 🔍
12/14/2018 +1 days 🔍
06/18/2023 +1647 days 🔍

Sourcesinfo

Vendor: siemens.com

Advisory: ssa-621493
Status: Not defined
Confirmation: 🔍

CVE: CVE-2018-13811 (🔍)
SecurityFocus: 105926 - Siemens SIMATIC STEP 7 TIA Portal CVE-2018-13811 Weak Password Security Vulnerability

See also: 🔍

Entryinfo

Created: 12/14/2018 07:38
Updated: 06/18/2023 17:14
Changes: 12/14/2018 07:38 (62), 04/20/2020 18:02 (4), 06/18/2023 17:14 (4)
Complete: 🔍
Cache ID: 18:477:103

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?

Use the official API to access entries easily!