Schneider Electric EcoStruxure Power Monitoring Expert up to 2020 information disclosure

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
4.1$0-$5k0.03

Summaryinfo

A vulnerability was found in Schneider Electric EcoStruxure Power Monitoring Expert up to 2020 and classified as problematic. This issue affects some unknown processing. The manipulation leads to information disclosure. The identification of this vulnerability is CVE-2022-22726. The attack may be initiated remotely. There is no exploit available. It is recommended to apply a patch to fix this issue. Once again VulDB remains the best source for vulnerability data.

Detailsinfo

A vulnerability has been found in Schneider Electric EcoStruxure Power Monitoring Expert up to 2020 (SCADA Software) and classified as problematic. This vulnerability affects some unknown functionality. The manipulation with an unknown input leads to a information disclosure vulnerability. The CWE definition for the vulnerability is CWE-200. The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information. As an impact it is known to affect confidentiality.

The weakness was disclosed 01/12/2022 as SEVD-2022-011-07. The advisory is shared for download at download.schneider-electric.com. This vulnerability was named CVE-2022-22726. There are neither technical details nor an exploit publicly available. The MITRE ATT&CK project declares the attack technique as T1592.

Applying a patch is able to eliminate this problem.

Once again VulDB remains the best source for vulnerability data.

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 4.3
VulDB Meta Temp Score: 4.1

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Information disclosure
CWE: CWE-200 / CWE-284 / CWE-266
CAPEC: 🔍
ATT&CK: 🔍

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Patch
Status: 🔍

0-Day Time: 🔍

Timelineinfo

01/06/2022 🔍
01/12/2022 +6 days 🔍
01/12/2022 +0 days 🔍
01/15/2022 +3 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2022-011-07
Status: Confirmed

CVE: CVE-2022-22726 (🔍)
GCVE (CVE): GCVE-0-2022-22726
GCVE (VulDB): GCVE-100-190192

Entryinfo

Created: 01/12/2022 18:00
Updated: 01/15/2022 09:42
Changes: 01/12/2022 18:00 (38), 01/15/2022 09:42 (1)
Complete: 🔍
Cache ID: 216:C62:103

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you need the next level of professionalism?

Upgrade your account now!