Schneider Electric EcoStruxure Power Monitoring Expert up to 2020 Web Page Generation cross site scripting

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
2.5$0-$5k0.00

A vulnerability was found in Schneider Electric EcoStruxure Power Monitoring Expert up to 2020 (SCADA Software). It has been declared as problematic. Affected by this vulnerability is an unknown code block of the component Web Page Generation Handler. The manipulation with an unknown input leads to a cross site scripting vulnerability. The CWE definition for the vulnerability is CWE-79. As an impact it is known to affect integrity. An attacker might be able to inject arbitrary html and script code into the web site. This would alter the appearance and would make it possible to initiate further attacks against site visitors.

The weakness was published 01/12/2022 as SEVD-2022-011-07. It is possible to read the advisory at download.schneider-electric.com. This vulnerability is known as CVE-2022-22804 since 01/07/2022. The exploitation appears to be difficult. The attack can be launched remotely. The requirement for exploitation is a single authentication. It demands that the victim is doing some kind of user interaction. The technical details are unknown and an exploit is not publicly available. The attack technique deployed by this issue is T1059.007 according to MITRE ATT&CK.

Applying a patch is able to eliminate this problem.

Productinfoedit

Type

Vendor

Name

CPE 2.3infoedit

CPE 2.2infoedit

CVSSv3infoedit

VulDB Meta Base Score: 2.6
VulDB Meta Temp Score: 2.5

VulDB Base Score: 2.6
VulDB Temp Score: 2.5
VulDB Vector: 🔒
VulDB Reliability: 🔍

CVSSv2infoedit

AVACAuCIA
🔍🔍🔍🔍🔍🔍
🔍🔍🔍🔍🔍🔍
🔍🔍🔍🔍🔍🔍
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔒
VulDB Temp Score: 🔒
VulDB Reliability: 🔍

Exploitinginfoedit

Class: Cross site scripting
CWE: CWE-79
ATT&CK: T1059.007

Local: No
Remote: Yes

Availability: 🔒
Status: Not defined
Price Prediction: 🔍
Current Price Estimation: 🔒

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfoedit

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfoedit

Recommended: Patch
Status: 🔍

0-Day Time: 🔒

Patch: download.schneider-electric.com

Timelineinfoedit

01/07/2022 CVE assigned
01/12/2022 +5 days Advisory disclosed
01/12/2022 +0 days VulDB entry created
01/15/2022 +3 days VulDB last update

Sourcesinfoedit

Vendor: https://www.schneider-electric.com/

Advisory: SEVD-2022-011-07
Status: Confirmed

CVE: CVE-2022-22804 (🔒)

Entryinfoedit

Created: 01/12/2022 06:03 PM
Updated: 01/15/2022 09:51 AM
Changes: (1) source_cve_assigned
Complete: 🔍

Comments

No comments yet. Languages: en.

Please log in to comment.

Might our Artificial Intelligence support you?