Schneider Electric EcoStruxure Operator Terminal Expert signature verification

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.2$0-$5k0.00

A vulnerability, which was classified as critical, was found in Schneider Electric EcoStruxure Operator Terminal Expert and EcoStruxure Pro-face BLUE (SCADA Software) (the affected version unknown). This affects an unknown part. The manipulation with an unknown input leads to a signature verification vulnerability. CWE is classifying the issue as CWE-347. The product does not verify, or incorrectly verifies, the cryptographic signature for data. This is going to have an impact on confidentiality, integrity, and availability. The summary by CVE is:

A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).

The weakness was presented 11/04/2022 as SEVD-2022-284-01. It is possible to read the advisory at se.com. This vulnerability is uniquely identified as CVE-2022-41666 since 09/27/2022. The technical details are unknown and an exploit is not publicly available.

There is no information about possible countermeasures known. It may be suggested to replace the affected object with an alternative product.

See VDB-212965, VDB-212967, VDB-212968 and VDB-212977 for similar entries.

Productinfo

Type

Vendor

Name

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.3
VulDB Meta Temp Score: 7.2

VulDB Base Score: 7.0
VulDB Temp Score: 6.8
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 7.8
NVD Vector: 🔍

CNA Base Score: 7.0
CNA Vector (Schneider Electric SE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Signature verification
CWE: CWE-347 / CWE-345
CAPEC: 🔍
ATT&CK: 🔍

Local: Yes
Remote: No

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: no mitigation known
Status: 🔍

0-Day Time: 🔍

Timelineinfo

09/27/2022 🔍
11/04/2022 +38 days 🔍
11/04/2022 +0 days 🔍
12/04/2022 +30 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2022-284-01
Status: Not defined

CVE: CVE-2022-41666 (🔍)
See also: 🔍

Entryinfo

Created: 11/04/2022 13:41
Updated: 12/04/2022 14:16
Changes: 11/04/2022 13:41 (47), 12/04/2022 14:16 (12)
Complete: 🔍
Cache ID: 18:880:103

Discussion

No comments yet. Languages: en.

Please log in to comment.

Are you interested in using VulDB?

Download the whitepaper to learn more about our service!