Schneider Electric Data Center Expert prior 7.9.0 insufficiently protected credentials

CVSS Meta Temp Score
CVSS is a standardized scoring system to determine possibilities of attacks. The Temp Score considers temporal factors like disclosure, exploit and countermeasures. The unique Meta Score calculates the average score of different sources to provide a normalized scoring system.
Current Exploit Price (≈)
Our analysts are monitoring exploit markets and are in contact with vulnerability brokers. The range indicates the observed or calculated exploit price to be seen on exploit markets. A good indicator to understand the monetary effort required for and the popularity of an attack.
CTI Interest Score
Our Cyber Threat Intelligence team is monitoring different web sites, mailing lists, exploit markets and social media networks. The CTI Interest Score identifies the interest of attackers and the security community for this specific vulnerability in real-time. A high score indicates an elevated risk to be targeted for this vulnerability.
7.3$0-$5k0.00

A vulnerability was found in Schneider Electric Data Center Expert (SCADA Software). It has been declared as problematic. This vulnerability affects an unknown function. The manipulation with an unknown input leads to a insufficiently protected credentials vulnerability. The CWE definition for the vulnerability is CWE-522. The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval. As an impact it is known to affect confidentiality. CVE summarizes:

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)

The weakness was shared 01/31/2023 as SEVD-2022-165-04. The advisory is available at download.schneider-electric.com. This vulnerability was named CVE-2022-32520 since 06/07/2022. The technical details are unknown and an exploit is not available. This vulnerability is assigned to T1552 by the MITRE ATT&CK project.

Upgrading to version 7.9.0 eliminates this vulnerability.

Productinfo

Type

Vendor

Name

Version

License

CPE 2.3info

CPE 2.2info

CVSSv4info

VulDB CVSS-B Score: 🔍
VulDB CVSS-BT Score: 🔍
VulDB Vector: 🔍
VulDB Reliability: 🔍

CVSSv3info

VulDB Meta Base Score: 7.4
VulDB Meta Temp Score: 7.3

VulDB Base Score: 4.3
VulDB Temp Score: 4.1
VulDB Vector: 🔍
VulDB Reliability: 🔍

NVD Base Score: 9.8
NVD Vector: 🔍

CNA Base Score: 8.0
CNA Vector (Schneider Electric SE): 🔍

CVSSv2info

AVACAuCIA
💳💳💳💳💳💳
💳💳💳💳💳💳
💳💳💳💳💳💳
VectorComplexityAuthenticationConfidentialityIntegrityAvailability
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock
unlockunlockunlockunlockunlockunlock

VulDB Base Score: 🔍
VulDB Temp Score: 🔍
VulDB Reliability: 🔍

Exploitinginfo

Class: Insufficiently protected credentials
CWE: CWE-522
CAPEC: 🔍
ATT&CK: 🔍

Local: No
Remote: Yes

Availability: 🔍
Status: Not defined

EPSS Score: 🔍
EPSS Percentile: 🔍

Price Prediction: 🔍
Current Price Estimation: 🔍

0-Dayunlockunlockunlockunlock
Todayunlockunlockunlockunlock

Threat Intelligenceinfo

Interest: 🔍
Active Actors: 🔍
Active APT Groups: 🔍

Countermeasuresinfo

Recommended: Upgrade
Status: 🔍

0-Day Time: 🔍

Upgrade: Data Center Expert 7.9.0

Timelineinfo

06/07/2022 🔍
01/31/2023 +238 days 🔍
01/31/2023 +0 days 🔍
02/25/2023 +25 days 🔍

Sourcesinfo

Vendor: schneider-electric.com

Advisory: SEVD-2022-165-04
Status: Confirmed

CVE: CVE-2022-32520 (🔍)

Entryinfo

Created: 01/31/2023 14:31
Updated: 02/25/2023 16:58
Changes: 01/31/2023 14:31 (49), 02/25/2023 16:58 (11)
Complete: 🔍
Cache ID: 18:D71:103

Discussion

No comments yet. Languages: en.

Please log in to comment.

Do you want to use VulDB in your project?